Installation
Install Remote Battery and Wall Switch Kit
RBWSK (required)
The Remote Battery and Wall Switch Kit is provided
with this appliance. It must be connected to the
receiver in the fi replace.
 Caution
Do not put batteries in the receiver as leaking
acid could damage its circuit board.
Material required
• 4 AA 1.5V alkaline batteries supplied with the engine
• Remote Battery and Wall Switch Kit, which contains:
• 1 Wall Switch
• 2 Screws
• 1 Battery Holder
• 1 Plate with magnets
• 1 Battery Cover assembly
• 1 Harness assembly - 35 ft
• 1 Junction Box
• 1 Cover plate and Screws
• 1 Cable tie
Installation
The receiver is located behind the appliance's front
panel, at the right of the control valve. It is maintained
in position with Velcro bands.
1. From the front of the appliance through the ac-
cess panel, grab the wire harness threaded from
the back and bring it towards the receiver at the
front of the appliance.
2. Pull out the receiver from its location to connect
the wiring harness power connector to receiver's
jack.
Remote Battery & Wall Switch Kit
 Caution
Do not run the switch wire over the top of the
firebox. Route the wire so it does not contact
the firebox.
3. Connect the harness' white connector to the auxil-
lary 5-pin junction on the receiver.
4. Run the harness assembly to the mounted posi-
tion of the junction box, securing the harness to
the framing using insulated staples (not supplied).
5. Feed the harness assembly through a restrain on
the rear of the junction box, feeding through until
the harness sheath is pinched by the retainer and
ensuring suffi cent length to make the connection
to the rear of the switch and battery holder.
6. Secure the junction box to the mounting surface
using appropriate fasteners (not supplied).
31