Alarm notifications
[E-mail] – global enable/disable E-mail notification;
[SNMP] – global enable/disable SNMP notification;
[GPO] – global enable/disable GPO actions.
NOTE:
If the monitoring option is disabled, notifications will not be sent, nevertheless whether
they are enabled or disabled.
RF, HD DAAI, HD CDNR, FM/IP Left Audio, FM/IP Right Audio Alarms
The settings applied to these alarms - are identical and are explained in details below.
Range – interactive slider used to adjust the Low&High thresholds at which an alarm will be
generated;
Thresholds – sets the desired Low&High thresholds (as explained above) but in figures.
Trigger Time – waiting time before active alarm is generated;
Release Time – waiting time before idle alarm is generated;
Once the Range, Thresholds, Trigger and Release times are set, the preferred alarm type should
be selected.
PLEASE HAVE IN MIND
not be sent, and the event will only be registered in the Log.
HD Radio Loss, Stereo Loss, IP Link, Internet Stream Alarms
The settings applied to these alarms are identical and are explained in details below.
Enable – In order for the alarm to be generated, the function should be enabled;
Trigger Time – waiting time before active alarm is generated;
Release Time – waiting time before idle alarm is generated.
HD Radio Loss Alarm, Stereo Loss Alarm, IP Link Alarm and Internet Stream Alarm are
flags related alarms, meaning that:
- HD Radio Loss – when the indicator points at OK on the interactive slider, the device is
working properly. If the indicator is under No signal, an alarm will be generated because of HD
Radio Loss.
- Stereo Loss – when the indicator points at Stereo on the interactive slider, the device is
working properly. If the indicator is under Mono, an alarm will be generated because of Stereo
loss.
- IP Link – when the indicator points at UP on the interactive slider, the device is working
properly.If the indicator is under Down, an alarm will be generated because the IP link is lost.
- Internet Stream – when the indicator points at Connected on the interactive slider, the device
is working properly. If the indicator is under Idle, an alarm will be generated because the device
will not be able to obtain stream.
We recommend, as a preferred notification method in case IP Link alarm is generated, GPO
to be set as when IP link is missing Email and SNMP could not be sent, and he event will only be
registered in the Log. You will be notified of the event upon the IP link is restored.
NOTE:
For detailed information on Alarm trigger and notifications refer to
Alarm Triggers" on page
E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com
that if the alarm notification is globally disabled, notification will
59.