parameter level becomes stable, within thresholds, and the alarm Trigger time is not elapsed,
then the Alarm Trigger remains in Idle state. If the alarm Trigger time expires and the parameter
level is still beyond limits, the Alarm trigger would change its state to High/Low. This would
result in predefined actions - alarm notifications (E-mail, SNMP trap) and save a log record. The
state will not be immediately switched into Idle when the parameter stabilizes, within threshold
levels, not up until the alarm Release time is elapsed. Meanwhile, if the parameter crosses again
any threshold, the Alarm trigger will remain in active state. If the parameter remain within the
threshold levels and the alarm Release time expires, then the Alarm trigger would switch into Idle
state and again predefined actions would be initiated.
Hi Threshold
Alarm Idle
No Alarm
E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com
Period > Alarm Trigger Time
Period < Alarm Trigger Time
Alarm Idle
- 60 -
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
Notification
for Active Alarm
No Alarm
Alarm Active
Notification
for Idle Alarm
Period > Alarm Release Time
TIME
Alarm Idle