4. USING THE OPERATION PANEL (ADVANCED OPERATIONS)

4-4. Setting the counters

The lower thread counter, production counter and needle replacement counter are available.
The three counters can be operated at the same time.

4-4-1. Lower thread counter

The lower thread counter can be used to let you know approximately how much lower thread is remaining.
* This function is only displayed when "A09: Lower thread counter operation" is set to "ON".
Refer to "4-6-6. Setting lower thread counter operation".
<Setting the lower thread counter initial value>
1
2
<Lower thread counter operation>
・ The lower thread counter can be used to let you know approximately how much lower thread is remaining.
* The lower thread counter should be used as a guide only.
・ The value displayed by the lower thread counter display is reduced by 0.1 from the initial setting value each time the number
of stitches x sewing pitch reaches 0.1 m, and a warning is given when the counter goes below 0.
・ Sewing will be possible even after the treadle is returned to the neutral position and the sewing machine stops. However,
after the treadle has been depressed backward and thread trimming has been carried out, sewing using the treadle will no
longer be possible.
If the treadle is depressed at this time, " Ent" will appear in the display. When the treadle is returned to the neutral position,
the display will return to the current counter display.
・ If the
key is pressed during a warning, the
carried out using the treadle.
If the A
key is pressed again for 2 seconds or more, the counter display will return to the initial value and counting from
the initial value will be possible.
19
Press the
key so that the
・ The lower thread counter value will appear in the 4-digit display.
Press the A
key for 2 seconds or more, and then press the C
or D
key to set the initial value.
・ When the D
key is pressed, the setting value increases by 0.1.
・ When the C
key is pressed, the setting value decreases by
0.1.
NOTE:
・ The setting range is from 0.1 to 99.9.
When the warning occurs, the counter indicator blinks and the buzzer sounds
for 5 seconds.