Pyronix BUMBT!8 Installation Instructions Manual
Pyronix BUMBT!8 Installation Instructions Manual

Pyronix BUMBT!8 Installation Instructions Manual

Led remote keypad
Table of Contents

Advertisement

Quick Links

BUMBT
INSTALLATION INSTRUCTIONS
Pyronix Ltd
This Product is approved for use in the
Residential, Commercial and Light Industrial Environment.
LED Remote Keypad
!
!
1
3
2
B
C
5
6
9
®
8
!
4
SET
8
®
October 2001
Rins 181 Issue7

Advertisement

Table of Contents
loading

Summary of Contents for Pyronix BUMBT!8

  • Page 1 BUMBT INSTALLATION INSTRUCTIONS LED Remote Keypad ® ® Pyronix Ltd October 2001 This Product is approved for use in the Residential, Commercial and Light Industrial Environment. Rins 181 Issue7...
  • Page 2: Programmable Output

    This product is sold subject to our standard warranty conditions and is warranted against defects in workmanship for a period of 2 years. In the interest of continuing improvement of quality, customer care and design, Pyronix reserve the right to amend specifications without giving prior notice.
  • Page 3: Table Of Contents

    CONTENTS INTRODUCTION SAFETY ACCESS LEVELS Limited User Master User Engineer FUNCTIONAL DESCRIPTION Operating Modes Entry / Exit Mode ZONES Engineer Programmable Zones DIAL OUT REPORTING FUNCTIONS INSTALLATION AND WIRING Plan View With Cover Removed PANEL ASSEMBLY POWER CONNECTIONS 10.1 Connections 10.2 Battery Connections 10.3...
  • Page 4: System Option

    11.11.12 Zone Alarm Reporting Codes 11.11.13 Zone Tamper Alarm Report Codes 11.11.14 System set / unset Reporting Codes 11.11.15 User Set Reporting Codes 11.11.16 User Unset Reporting Codes 11.11.17 Maintenance and Priority Codes 11.11.18 Restoral Reporting Codes 11.11.19 Digicom Codes 11.11.20 Keyswitch Set Configuration 11.11.21 Group Reporting Telephone Allocation 11.11.22 Engineer NVM Reset...
  • Page 5: Introduction

    INTRODUCTION The Atlas 8 is a fully featured intruder alarm control panel, based around a micro-controller with 8 fully programmable zones. It may be operated via a single Remote Keypad, a maximum of 3 remote keypads (Atlas RKPs) may be fitted at convenient points around the premises.
  • Page 6: Entry / Exit Mode

    Entry / Exit Mode Entry When the panel is set and an Entry / Exit zone is triggered the Entry / Exit timer will begin to countdown. During this period an Entry / Exit tone (single repeated bleep) will be produced by the internal sounder and any zones which are programmed as Access zones will be ignored.
  • Page 7: Dial Out Reporting

    DIAL OUT REPORTING The Atlas 8 has the capability to send messages of alarm status to a Central Receiving Station. Every time the alarm status changes i.e. Alarm Set/Unset, System Fault or Alarm Actuation a message is sent to the CRS informing it of the status change.
  • Page 8 Follow Line Fail: This option will allow the programmable output to switch on when a line fail occurs and switch off when the line is active again. Follow Kiss Off: This option will allow the programmable output to switch on for a few seconds when a communication kiss off has been successfully completed.
  • Page 9 System Option 3. The system may be configured for use with the following: Engineer Code Lock N.V.M Reset: This option allows the control panel programmable settings to be reverted back to factory default when in Engineer mode only. Engineer Power Up N.V.M Reset: This allows the control panel programmable settings to be reverted back to factory default when in User Mode.
  • Page 10 System Option 4 Bell Squawk- Upon expiry of the exit time, if the panel sets OK the bell will emit a short duration of sound. It will also emit a short duration of sound upon disarming. Default value - OFF. Bell Time Minutes/Seconds- This option allows for very short bell durations.
  • Page 11: Installation And Wiring

    INSTALLATION AND WIRING Before beginning any installation work read through this section carefully. Plan out the various areas and degrees of protection required from each zone. It is important to decide which type each zone should be if selective sets are to be used.
  • Page 12: Panel Assembly

    PANEL ASSEMBLY Take off the front cover and remove the cardboard packaging containing the control panel and PCB. Push in the PCB support posts from the rear of the panel as shown. If required assemble the tamper switch from the optional kit of parts as indicated. If necessary place the transformer and fasten into position using the screws supplied with the transformer kit.
  • Page 13 Hang the control panel base onto the wall with the central mounting hole using one of the screws and plugs from the screw pack. If possible use a spirit level or some other means to position the control panel squarely then drill two more holes into the wall to locate the other two screws and plugs.
  • Page 14: Power Connections

    POWER CONNECTIONS 10.1 Connections The Atlas 8 requires a supply of 17V a.c. from the power supply unit or transformer, with a current capacity of 1 amp. Connect the 17V current to the terminals marked 17~ on the PCB. 17V a.c 10.2 Battery Connection In order for the Atlas 8 to operate if the mains power is cut a battery back-up is required.
  • Page 15: Battery Capacity

    Non alarm current for control panel (7hrs 40min) 130mA (0.130 A) Steady state current for detectors 120mA (0.120 A) (e.g. 8 x 15mA for 8 hours - Pyronix PIRs) Typical standby current for external sounder 50mA (0.050 A) (e.g. Self Actuating Bell for 8 hours) Typical on state current for external sounder (20 mins) : 350mA (0.35 A)
  • Page 16: Atlas 8 End Of Line Resistor Wiring Diagram

    10.6.2 Atlas 8 Double Pole Zone Wiring Diagram. Wiring two or more sensors with end of line resistors to a single zone. NOTE: only one 2K2 resistor should be used per zone. The 2K2 resistor should be installed into the last detector in series to protect all the zone tamper wiring.
  • Page 17: Atlas End Of Line Wiring Diagram

    Rins 181 Issue7 Page 17...
  • Page 18 Page 18...
  • Page 19: Programming

    PROGRAMMING 11.1 Factory Defaults The panel is preprogrammed to the factory settings shown below. Master User code : 1234 (0000-9999) Limited User code : 5678 (0000-9999) Engineer code : 9999 (0000-9999) Bell timer : 20 minutes (programmable 2 to 20 mins) Entry : 30 seconds (programmable 2 to 255 secs) Exit...
  • Page 20: Setting The Panel When Mains Fails

    11.5 Setting the Panel when Mains Fails Under normal operation the panel will indicate a fault condition if the AC supply is disconnected. It will still be possible to Set and Unset the control panel during a mains fail and no further action is required. Full functionality of the control panel is available during mains fail.
  • Page 21: Changing The Engineer Code

    11.10 Changing the Engineer Code Enter then The old Engineer Code - gives an audible acceptance tone (Factory Set at 9999) then the new Engineer Code - gives an audible acceptance tone then the new Engineer Code again- gives an audible acceptance tone If an incorrect key is entered an error tone will be given and the function ended.
  • Page 22: System Option

    11.11.3 System Option 1 Enter followed by . The RKP LEDs will toggle on and off indicating the selection made. Function LED ON LED OFF Alarm Double pole zones End of line zones Tamper User log reset enable User log reset disable P.A.
  • Page 23: Programmable Re-Sets

    11.11.7 Programmable Re-sets Enter followed by a single digit = continuous re-setting) 11.11.8 Central Monitoring Station Telephone Number Enter followed by the telephone number. (Up to 16 digits) By pressing the a " " is displayed to cause a 2 second pause during dial out. Press to store entry.
  • Page 24: Zone Tamper Alarm Report Codes

    11.11.13 Zone Tamper reporting Codes Enter Enter 2 digits for each tamper zone. To disable an event insert blanks for both digits. To use HEX codes, use the key to select the character required and the key to accept. Example Tamper zone 1 Tamper zone 2 Tamper zone 3...
  • Page 25: User Unset Reporting Codes

    11.11.16 User Unset reporting codes Enter Enter 2 digits for seven reporting codes. To disable an event insert blanks for both digits. To use HEX codes, use the key to select the character required and the key to accept. Example Unset User 1 Unset User 2 Unset User 3...
  • Page 26: Digicom Codes

    11.11.19 Digicom Codes Enter Enter digit 0 - 6 . SIA DTMF SIA pulse format P1 - 1400 Hz handshake 10pps SIA pulse format P2- 2300 Hz handshake 20pps SIA pulse format P3 - 1400 Hz handshake 20pps Reserved Reserved Reserved 11.11.20 Keyswitch Set Configuration Enter...
  • Page 27: System Faults

    SYSTEM FAULTS There are 6 fault conditions automatically detected by the Atlas 8. The user is informed of a fault via the fault LED. This LED will illuminate and an error tone will be emitted every 5 seconds when the panel is in day mode, Press a function key to stop the error tone.
  • Page 28: Technical Specification

    TECHNICAL SPECIFICATION 13.1 Power supply Power input : 17V a.c. Low voltage output : 13.2 Vdc fused, 1.25 Amp maximum Including Control Panel. 1Amp maximum available for external devices. Low voltage output fuses : 1 Amp quick blow. Battery charge voltage : 13.7 V d.c.
  • Page 29: Engineer Quick Reference Programming

    ENGINEER QUICK REFERENCE PROGRAMMING SECTION Set A zone attributes. Set B zone attributes. Set C zone attributes. Set D zone attributes. Bell time Entry time Exit time Engineer code change Programmable outputs 1 Programmable outputs 2 System option 1 System option 2 System option 3 Spare Re-Sets...
  • Page 30: Communication Programming

    COMMUNICATION PROGRAMMING Programmable Outputs Programmable Output 1 Default Off Programmable Output 2 Default Off System Option 1 Default - End of line Default - User Log Re-set disabled Default - Tone Dial Default - Internal sounder only on tamper activation System Option 2 Default - 24 hour test dial Default - no-dial in...
  • Page 31 Event reporting Codes Zone Alarm Reporting Codes. Zone 1 Alarm Zone 2 Alarm Zone 3 Alarm Zone 4 Alarm Zone 5 Alarm Zone 6 Alarm Zone 7 Alarm Zone 8 Alarm Tamper Alarm Reporting Codes. Zone 1 Tamper Zone 1 Tamper Zone 1 Tamper Zone 1 Tamper Zone 1 Tamper...
  • Page 32 User Set Reporting Codes Set User 1 Set User 2 Set User 3 Set User 4 Set User 5 Set User 6 Set User 7/Keyswitch User Unset Reporting Codes Unset User 1 Unset User 2 Unset User 3 Unset User 4 Unset User 5 Unset User 6 Unset User...
  • Page 33 Restoral Reporting Codes User code Restoral Bell Timeout Restoral Battery Restoral A.C. Restoral Test Transmission Digicom Codes Keyswitch Configuration Group Allocation Group 1 Group 2 Group 3 24hr. Test Call Rins 181 Issue7 Page 33...
  • Page 34: Atlas 8 Service History

    Page 34...
  • Page 35: Zone Programming Label

    Rins 181 Issue7 Page 35...