Gas Connection - BORETTI CFBG902AN Instruction On Mounting And Use Manual

Table of Contents

Advertisement

Available languages

Available languages

A)

GAS CONNECTION

NL
Cat:
The gases used for the operation of
cooking appliances may be grouped by
their characteristics into two types:
G25.3 Natural gas
G20 Natural gas
G30 / G31 Butane/Propane
The fitting (fig. 9.2) is made up of:
A - Gas train terminal fitting (rh or lh)
B - Gasket
C - Conical connector
Use rigid or flexible connection pipes
which comply with applicable regulations.
If compression fittings are used, tighten
firmly using two spanners (fig. 9.4).
In particular, make sure that:
the flexible hose does not come into
contact with any parts of the cooker
with surface temperatures in excess
of 70˚C;
the flexible hose does not exceed 75
cm in length and does not come into
contact with sharp edges or corners;
the hose is not under tension or
twisted and is not kinked or too tightly
bent;
A
B
C
1/2" gaz conique
II
2EK3B/P
NL
Fig. 9.2
the connection with rigid metal pipes
should not cause stresses to the gas
ramp.
we advise replacing the gasket on
the slightest sign of deformation or
imperfection.
the hose can easily be inspected
along its entire length to check its
condition; hoses should replaced after
a maximum of three years.
the cylinder cock or the supply cock
immediately ahead of the appliance
is closed whenever the cooker is not
in use.
This appliance was configured for
the appliance category K (I
is suitable for the use of G and G+
distribution gases according to
the specifications as included in
the NTA 8837:2012 Annex D with a
Wobbe index of 43.46 – 45.3 MJ/m
(dry, 0 °C, upper value) or 41.23 –
42.98 (dry, 15 °C, upper value).
This
appliance
be converted and/or again be
calibrated
for
category E (I
).
2E
This therefore implies that the
appliance: "is suitable for G+ gas
and H gas or is demonstrably
suitable for G+ gas and can
demonstrably be made suitable
for H gas" within the meaning of
the "Dutch Decree of 10 May 2016
regarding amendment of the Dutch
Gas Appliances Decree...".
) and
2K
3
can
moreover
the
appliance
219

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents