Error 110

Error Message Displayed to user
E110
Condition
LifePulse Module firmware update failed.
Cause
• Update image is corrupted
• Intermittent connection issues
• Damaged LifePulse module
Remedy
• Re-download software update, retry software update.
• Check condition and connections of LifePulse cable, un-seat and re-seat connections, retry software update.
• Replace LifePulse board.
• Reprogram main PCBA.
• If reprogramming cannot be performed or still fails, replace console.