Error 93

Error Message Displayed to user
• E93
Condition
The RMS current drawn by the motor was excessive causing a step slowdown.
Cause
• Bad motor / wiring
• Bad Motor Controller
• Excessive user weight
• Jumping / pushing on steps
Remedy
• Check motor and motor cabling for damage. Repair / replace as needed.
• Is error repeatable? Check Motor Drive Board. If not repeatable, may have been due to user jumping on or pushing
steps.
• PowerMills can exceed current while trying to slow a user down. Could be caused by manner of use or user
characteristics.