Daikin Altherma R Hybrid Installer's Reference Manual page 218

Hide thumbs Also See for Altherma R Hybrid:
Table of Contents

Advertisement

6/7
Field settings table
Breadcrumb
Field code
Setting name
A.8
[9-0E]
--
A.8
[A-00]
--
A.8
[A-01]
--
A.8
[A-02]
--
A.8
[A-03]
--
A.8
[A-04]
--
A.8
[B-00]
--
A.8
[B-01]
--
A.8
[B-02]
--
A.8
[B-03]
--
A.8
[B-04]
--
A.8
[C-00]
Domestic heating water priority.
A.8
[C-01]
--
A.8
[C-02]
--
A.8
[C-03]
--
A.8
[C-04]
--
A.8
[C-05]
What is the thermo request contact type for the main zone?
A.8
[C-06]
What is the thermo request contact type for the add. zone?
A.8
[C-07]
What is the unit control method in space operation?
A.8
[C-08]
Which type of external sensor is installed?
A.8
[C-09]
What is the required alarm output contact type?
A.8
[C-0A]
Indoor quick heat-up function
A.8
[C-0C]
High electricity price decimal (Do not use)
A.8
[C-0D]
Medium electricity price decimal (Do not use)
A.8
[C-0E]
Low electricity price decimal (Do not use)
A.8
[D-00]
--
A.8
[D-01]
Forced off contact
A.8
[D-02]
Which type of DHW pump is installed?
A.8
[D-03]
Leaving water temperature compensation around 0°C.
A.8
[D-04]
Is a demand PCB connected?
A.8
[D-05]
--
A.8
[D-07]
Is a solar kit connected?
A.8
[D-08]
Is an external kWh meter used for power measurement?
A.8
[D-09]
--
A.8
[D-0A]
Is an external gas meter used for power measurement?
A.8
[D-0B]
--
A.8
[D-0C]
What is the high electricity price (Do not use)
A.8
[D-0D]
What is the medium electricity price (Do not use)
A.8
[D-0E]
What is the low electricity price (Do not use)
A.8
[E-00]
Which type of unit is installed?
A.8
[E-01]
Which type of compressor is installed?
A.8
[E-02]
What is the indoor unit software type?
A.8
[E-03]
--
A.8
[E-04]
--
A.8
[E-05]
Can the system prepare domestic hot water?
A.8
[E-06]
Is a DHW tank installed in the system?
A.8
[E-07]
What kind of DHW tank is installed?
A.8
[E-08]
--
A.8
[E-09]
--
A.8
[E-0A]
--
A.8
[E-0B]
--
A.8
[E-0C]
--
A.8
[F-00]
--
A.8
[F-02]
--
A.8
[F-03]
--
A.8
[F-04]
--
A.8
[F-05]
--
A.8
[F-06]
--
A.8
[F-09]
--
A.8
[F-0A]
--
4P471775-1B - 2021.02
Range, step
Default value
0~8,step:1
6
0
0
0
0
0
0
0
0
0
0
R/W
0: Solar priority
1: Heat pump priority
0
0
0
3
R/W
1: Thermo ON/OFF
2: C/H request
R/W
0: -
1: Thermo ON/OFF
2: C/H request
R/W
0: LWT control
1: Ext RT control
2: RT control
R/W
0: No
1: Outdoor sensor
2: Room sensor
R/W
0: Normally open
1: Normally closed
R/W
0: Disable
1: Enable
R/W
0~7
4
R/W
0~7
4
R/W
0~7
4
0
R/W
0: No
1: Open tariff
2: Closed tariff
3: Thermostat
R/W
0: No
1: Secondary rtrn
2: Disinf. Shunt
3: Circul. Pump
4: CP & disinf. Sh
R/W
0: Disabled
1: Enabled, shift 2°C (from -2 to 2°C)
2: Enabled, shift 4°C (from -2 to 2°C)
3: Enabled, shift 2°C (from -4 to 4°C)
4: Enabled, shift 4°C (from -4 to 4°C)
R/O
0: No
1: Pwr consmp ctrl
1
R/W
0: No
1: Yes
R/O
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
0
R/O
0: Not present
1: 1 /m³
2: 10 /m³
3: 100 /m³
2
R/W
0~49
20
R/W
0~49
20
R/W
0~49
15
R/O
0~5
3: Hybrid
R/O
0: 08
R/O
1: Type 2
0
R/O
0
R/W
0: No
1: Yes
R/W
0: No
1: Yes
R/W
0~6
4: Type 5
6: Type 7
0
0
0
0
0
0
3
5
0
0
0
0
0
Installer setting at variance with
default value
Date
Value
CHYHBH*