  • Page 1 User reference guide Daikin Altherma 3 H HT F ETVZ16S18DA6V ETVZ16S23DA6V ETVZ16S18DA9W ETVZ16S23DA9W...
  • Page 2: Table Of Contents

    Using quiet mode ............................55 4.10.3 Using holiday mode ............................55 4.10.4 WLAN adapter ..............................56 5 Energy saving tips 6 Maintenance and service Overview: Maintenance and service ..........................59 User reference guide ETVZ16S18+23DA6V+9W Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 3 Symptom: The water at the tap is too cold........................61 Symptom: Heat pump failure ............................62 Symptom: The system is making gurgling noises after commissioning................. 62 8 Relocation Overview: Relocation ..............................64 9 Disposal 10 Glossary ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 4: Installer Settings: Tables To Be Filled In By Installer

    WD curve type [2.E] Additional zone (only if [4.4]=1, dual zone) Emitter type [3.7] Control (read only) [3.9] Setpoint mode [3.4] Schedule [3.1] WD curve type [3.C] (read only) Tank ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 5: Settings Menu

    WD curve type [5.E] (read only) 1.2 Settings menu Setting Fill in… Main zone Thermostat type [2.A] Additional zone (if applicable) Thermostat type [3.A] Information Dealer information [8.3] ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 6: Quick Guide

    The User pin code is 0000. User 0000 Advanced user pin code The Advanced user pin code is 1234. Additional menu items for the user are now visible. Advanced user 1234 ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 7: Space Heating/Cooling

    1 Go to [1]: Room. Room 2 Adjust the desired room temperature. °C – Room a Actual room temperature b Desired room temperature ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 8 There are 2 types of WD curves: slope-offset curve (default), and 2-points curve. If needed, you can change the type in [2.E] Main zone > WD curve type. The way to adjust the curve depends on the type. ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 9 For more information, see also: ▪ "4.4 Turning operation ON or OFF" [  29] ▪ "4.6 Space heating/cooling control" [  32] ▪ "4.8 Preset values and schedules" [  41] ▪ "4.9 Weather-dependent curve" [  50] ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 10: Domestic Hot Water

    There are 2 types of WD curves: slope-offset curve (default), and 2-points curve. If needed, you can change the type in [2.E] Main zone > WD curve type. The way to adjust the curve depends on the type. ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 11 For more information, see also: ▪ "4.4 Turning operation ON or OFF" [  29] ▪ "4.7 Domestic hot water control" [  37] ▪ "4.8 Preset values and schedules" [  41] ▪ "4.9 Weather-dependent curve" [  50] ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 12: General Information

    Do NOT place any objects containing water on the unit. CAUTION ▪ Do NOT place any objects or equipment on top of the unit. ▪ Do NOT sit, climb or stand on the unit. ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 13: About The Documentation

    ▪ Keep the documentation for future reference. Target audience End users Documentation set This document is part of a documentation set. The complete set consists of: ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 14 The original documentation is written in English. All other languages are translations. Daikin Residential Controller app If set up by your installer, you can use the Daikin Residential Controller app to control and monitor the status of your Daikin Altherma heat pump system. For more information, see: http://www.onlinecontroller.daikineurope.com/...
  • Page 15: Meaning Of Warnings And Symbols

    WARNING Indicates a situation that could result in death or serious injury. WARNING: FLAMMABLE MATERIAL CAUTION Indicates a situation that could result in minor or moderate injury. ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 16: About The System

    Cool down a space (if a heating/cooling heat pump model is installed) ▪ Produce domestic hot water INFORMATION Cooling is only applicable in case a conversion kit (EKHVCONV2) is installed. 3.3.1 Components in a typical system layout ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 17 User interface of the indoor unit e Dedicated Human Comfort Interface (BRC1HHDA used as room thermostat) f Underfloor heating g Radiators, heat pump convectors, or fan coil units ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 18: Operation

    Installer: 1 h Dials and buttons You use the dials and buttons: ▪ To navigate through the screens, menus and settings of the LCD screen ▪ To set values ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 19 : Turn the right dial. Navigate through the possible values and settings. ▪ : Press the right dial. Confirm your choice and go to the next menu item. ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 20: Menu Structure: Overview User Settings

    Only accessible by installer (***) Only applicable when WLAN adapter is installed INFORMATION Depending on the selected installer settings and unit type, settings will be visible/ invisible. ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 21: Possible Screens: Overview

    The most common screens are as follows: – Home screen Main menu screen Lower level screens: c1: Setpoint screen c2: Detailed screen with values c3: Screen with weather-dependent curve c4: Screen with schedule ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 22: Home Screen

    Smart energy is currently being used for domestic hot water. Space operation mode Cooling Heating Outdoor / quiet mode Measured outdoor temperature Quiet mode active Outdoor unit ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 23 Installed heat emitter type: Underfloor heating Fancoil unit Radiator Leaving water temperature setpoint ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 24 "7.1 To display the help text in case of a malfunction" [  60] for more information. If the corresponding operation (for example: space heating) is not active, the circle is greyed out. ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 25: Main Menu Screen

    User settings mode and quiet mode. Displays data and information about the Information indoor unit. Installer settings Restriction: Only for the installer. Gives access to advanced settings. ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 26 Restriction: Only for the installer. Commissioning Perform tests and maintenance. Change the active user profile. User profile Turn heating/cooling functionality and Operation domestic hot water preparation on or off. ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 27: Setpoint Screen

    Current temperature Measured by the unit Desired temperature Turn the right dial to increase/ decrease. Submenu Turn or press the left dial to go to the submenu. ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 28: Detailed Screen With Values

    Selected setting and value Possible actions on this screen Go through the list of settings. Change the value. Go to the next setting. Confirm changes and proceed. ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 29: Turning Operation On Or Off

    Room temperature control ON Room temperature control OFF Space heating/cooling operation Space heating/cooling operation ON Space heating/cooling operation OFF Tank heating operation Tank heating operation ON Tank heating operation OFF ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 30: To Turn On Or Off

    Tank), disinfection mode will remain active. However, if you turn it OFF while disinfection is running, an AH error occurs. 1 Go to [C.3]: Operation > Tank. Operation Space heating/cooling Tank 2 Set operation to On or Off. ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 31: Reading Out Information

    [8.8] Connection status Information about the connection status of the unit, the room thermostat and the LAN adapter. [8.9] Running hours Running hours of specific system components ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 32: Space Heating/Cooling Control

    While the unit is in operation, the status indicator will light up blue constantly. To set the space operation mode 1 Go to [4.1]: Space heating/cooling > Operation mode ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 33: Determining Which Temperature Control You Are Using

    Check the installer settings table filled in by the installer. To determine which temperature control you are using (method 2) You can see on the home screen which temperature control you are using. ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 34: To Change The Desired Room Temperature

    The desired room temperature will return to its scheduled value whenever a scheduled action occurs. You can avoid scheduled behaviour by (temporarily) turning off scheduling. To turn off room temperature scheduling 1 Go to [1.1]: Room > Schedule. ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 35: To Change The Desired Leaving Water Temperature

    You can avoid scheduled behaviour by (temporarily) turning off scheduling. To turn off leaving water temperature scheduling 1 Go to one of the following: ▪ [2.1]: Main zone > Schedule ▪ [3.1]: Additional zone > Schedule ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 36 Operation 2 Select No. To enable weather-dependent operation for the leaving water temperature "4.9.4 Using weather-dependent curves" [  53]. ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 37: Domestic Hot Water Control

    4.7.2 Reheat mode In reheat mode the DHW tank continuously heats up to the temperature shown on the home screen (example: 50°C) when the temperature drops below a certain value. ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 38: Scheduled Mode

    (=reheat tank temperature – hysteresis value; example: 35°C), the DHW tank heats up until it reaches the reheat set point (example: 45°C). This ensures that a minimum amount of hot water is available at all times. Example: ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 39: To Change The Domestic Hot Water Temperature

    Activate or deactivate Powerful operation as follows: 1 Go to [5.1]: Tank > Powerful operation 2 Turn powerful operation Off or On. ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 40 When powerful operation is active, the risk of space heating/cooling and capacity shortage comfort problems is significant. In case of frequent domestic hot water operation, frequent and long space heating/cooling interruptions will happen. ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 41: Preset Values And Schedules

    Electricity: 12 euro cents/kWh [7.5.1]=12 To set the gas price 1 Go to [7.6]: User settings > Gas price. 2 Select the correct gas price. 3 Confirm the changes. ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 42 To set the electricity price in case of an incentive per kWh renewable energy Calculate the value for the electricity price with following formula: ▪ Actual electricity price+Incentive/kWh ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 43 Gas price=4.08+(5×0.9) Gas price=8.58 Calculation of the electricity price Electricity price=Actual electricity price+Incentive/kWh Electricity price=12.49+5 Electricity price=17.49 Price Value in breadcrumb Gas: 4.08 /kWh [7.6]=8.6 Electricity: 12.49 /kWh [7.5.1]=17 ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 44: Using And Programming Schedules

    Most quiet [7.5.4] User settings > Program when a certain electricity tariff is valid. Electricity price > Schedule Example of programming a schedule "4.8.4 Schedule screen: Example" [  45]. ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 45: Schedule Screen: Example

    To clear the content of the week schedule 1 Select the name of the current schedule. User defined 1 2 Select Delete. Delete Rename Select 3 Select OK to confirm. ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 46 In this example, Monday is the first day you programmed. Thus, the last programmed action is valid up to the first action of next Monday. ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 47 5 Repeat this action for all other weekdays. — User defined 1 To program the schedule for Saturday and copy it to Sunday 1 Select Saturday. 2 Select Edit. ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 48 INFORMATION Not all schedules can be renamed. Usage example: You work in a 3-shift system If you work in a 3-shift system, you can do the following: ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 49 1 Program 3 room temperature schedules in heating mode and give them appropriate names. Example: EarlyShift, DayShift and LateShift 2 Select the schedule that you currently want to use. ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 50: Weather-Dependent Curve

    See "4.9.4 Using weather-dependent curves" [  53]. 4.9.2 2-points curve Define the weather-dependent curve with these two setpoints: ▪ Setpoint (X1, Y2) ▪ Setpoint (X2, Y1) ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 51: Slope-Offset Curve

    Examples Weather-dependent curve when slope is selected: ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 52 The icon corresponds to the heat emitter for that zone: ▪ : Underfloor heating ▪ : Fan coil unit ▪ : Radiator ▪ : Domestic hot water tank ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 53: Using Weather-Dependent Curves

    [2.5] Main zone > Heating WD curve Main zone – Cooling [2.6] Main zone > Cooling WD curve Additional zone – Heating [3.5] Additional zone > Heating WD curve ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 54 Cold Cold ↑ ↑ ↑ ↑ Cold ↓ ↑ ↓ ↑ — ↓ — ↓ Cold ↑ ↓ ↑ ↓ ↓ ↓ ↓ ↓ "4.9.2 2-points curve" [  50]. ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 55: Other Functionalities

    Setting the starting date and ending date of your holiday. Activating the holiday mode. To check if holiday mode is activated and/or running is displayed on the home screen, holiday mode is active. ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 56: Wlan Adapter

    About the WLAN adapter The wireless LAN adapter connects the heat pump system to the internet. As user you can then control the heat pump system via the Daikin Residential Controller app. This needs the following components: WLAN adapter...
  • Page 57 See: http://www.onlinecontroller.daikineurope.com/ Configuration To configure the Daikin Residential Controller app, follow the in-app instructions. While doing this, the following actions and information are needed on the user interface of the indoor unit: [D] Wireless gateway...
  • Page 58: Energy Saving Tips

    Program to turn ON the domestic hot water pump only during periods of the day when instant hot water is necessary. Example: In the morning and evening. ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 59: Maintenance And Service

    Turn off any combustible heating devices, ventilate the room, and contact the dealer where you purchased the unit. Do NOT use the unit until a service person confirms that the part from which the refrigerant leaked has been repaired. ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 60: Troubleshooting

    Conditions: The user permission level is set to advanced end user. 1 Go to [8.2]: Information > Malfunction history. You see a list of the most recent malfunctions. ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 61: Symptom: You Are Feeling Too Cold (Hot) In Your Living Room

    DHW tank to a preset value (Eco setpoint = lower tank temperature) during the day. "4.8.3  Using programming schedules"    44] and "4.8.4  Schedule screen: Example" [  45]. ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 62: Symptom: Heat Pump Failure

    We recommend to purge air with the air purge function of the unit (to be performed by the installer). If you purge air from the heat emitters or collectors, mind the following: ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 63 If yes, make sure that the room where you want to purge air is sufficiently ventilated. Reason: Refrigerant might leak into the water circuit, and subsequently into the room when you purge air from the heat emitters or collectors. ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 64: Relocation

    If you want to relocate parts of your system (user interface, indoor unit, outdoor unit, DHW  tank…), contact your installer. You can find the contact/helpdesk number via the user interface. ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 65: Disposal

    Do NOT try to dismantle the system yourself: dismantling of the system, treatment of the refrigerant, oil and other parts MUST comply with applicable legislation. Units MUST be treated at a specialised treatment facility for reuse, recycling and recovery. ETVZ16S18+23DA6V+9W User reference guide Daikin Altherma 3 H HT F 4P586461-1A – 2020.01...
  • Page 66: Glossary

    Optional equipment Equipment made or approved by Daikin that can be combined with the product according to the instructions in the accompanying documentation. Field supply Equipment NOT made by Daikin that can be combined with the product according to the instructions in the accompanying documentation.
  • Page 68 4P586461-1A 2020.01 Verantwortung für Energie und Umwelt...