CHYHBH05+08AF + EHYKOMB33A
Daikin Altherma R Hybrid
4P471761-1E – 2020.10
CAUTION
The disinfection function settings MUST be configured by the installer according to
the applicable legislation.
CAUTION
Make sure to activate the disinfection function when a third-party tank is installed.
#
Code
[A.4.4.2]
[2‑00]
[A.4.4.1]
[2‑01]
[A.4.4.3]
[2‑02]
[A.4.4.4]
[2‑03]
[A.4.4.5]
[2‑04]
T
DHW
[2-03]
T
H
T
U
00.00
01.00
T
Domestic hot water temperature
DHW
T
User set point temperature
U
T
High set point temperature [2-03]
H
t Time
Operation day:
0: Each day
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday (default)
6: Saturday
7: Sunday
Disinfection
0: No (default)
1: Yes
Start time: 00~23:00, step: 1:00 (default:
23:00).
Temperature target: fixed value (default:
60°C)
Duration
Range 40~60 minutes (default: 40 minutes)
[2-04]
22.00
23.00
24.00
t
[2-02]
8
Configuration
|
Description
Installer reference guide