Configuration
Quick wizard: Options
Installer reference guide
110
#
Code
[A.2.1.9]
[F-0D]
#
Code
[A.2.1.9]
[F-0D]
Domestic hot water settings
Following settings must be made accordingly.
#
Code
[A.2.2.1]
[E‑05]
[A.2.2.2]
[E‑06]
Description
When the space heating control is OFF by the
user interface, the pump is always OFF, unless
pump operation is required due to safety
precautions. When the space heating control is
On, you can select the desired pump operation
mode (only applicable during space heating)
Pump operation mode:
0 (Continuous): Not applicable.
1 (Sample): Not applicable.
Description
<< continuation
2 (Request)(default): Pump operation based
on request. Example: Using a room thermostat
creates thermo ON/OFF condition. When there
is no such demand, the pump is OFF.
a
b
c
d
c
b
e
b
c
-
a: Space heating control (user interface)
-
b: OFF
-
c: On
-
d: Heating demand (by ext RT or RT)
-
e: Pump operation
Description
Domestic hot water preparation:
0 (No): NOT possible
1 (Yes)(default): Possible
Domestic hot water tank installed in the system?
0 (No)(default): the domestic hot water will be
produced by the boiler when there is a
demand.
1 (Yes): the domestic hot water will be
produced by the tank.
Note: For Switzerland, setting MUST be "1".
continued >>