Daikin Altherma R Hybrid Installer's Reference Manual page 143

Hide thumbs Also See for Altherma R Hybrid:
Table of Contents

Advertisement

Parameter
Setting
Maximum outside
temperature of the heat curve
Space heating pump post
purge period
Space heating pump post
purge period after domestic
hot water operation
Position 3-way valve or electric
valve
Booster
Step modulation
Minimal space heating rpm
.
Minimum capacity space
heating pump
Minimal domestic hot water
rpm
(not applicable for
Switzerland)
Minimal supply temperature
during OT demand.
(OpenTherm thermostat)
CHYHBH05+08AF + EHYKOMB33A
Daikin Altherma R Hybrid
4P471761-1E – 2020.10
Range
Default
settings
15°C~30°C
25°C
0~15 min
1 min
0~15 min
1 min
0~3
0~1
0~1
23%~50%
23%
23%~50%
23%
10°C~16°C
40°C
8
Configuration
|
Description
Do NOT modify this setting on
the boiler. Use the user
interface instead.
Changing this setting has no
effect on the operation of the
unit.
Changing this setting has no
effect on the operation of the
unit.
0
0=Powered
heating
1=Powered during domestic
hot water
2=Powered
heat demand (space heating,
domestic hot water, eco/
comfort)
3=Zone regulation
4 and higher=Not applicable
0
Changing this setting has no
effect on the operation of the
unit.
1
0=OFF during space heating
operation
1=ON during space heating
operation
It is recommended not to
modify this setting.
Adjustment range 23~50%
(40=propane).
It is recommended not to
modify this setting in case of
natural gas.
40
There is no space heating
pump in the gas boiler.
Changing this setting has no
effect.
Adjustment range 23~50%
(40=propane).
It is recommended not to
modify this setting in case of
natural gas.
Changing this setting has no
effect on the operation of the
unit.
during
space
during
every
Installer reference guide
143