Additional installation site requirements of the outdoor unit in cold climates..........57 6.1.3 Installation site requirements of the indoor unit ..................57 Opening and closing the units ............................58 Installer reference guide EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 3
Configuration wizard............................... 118 Possible screens ................................119 9.3.1 Possible screens: Overview ..........................119 9.3.2 Home screen..............................120 9.3.3 Main menu screen............................123 9.3.4 Menu screen..............................124 EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 4
Solving problems based on error codes ......................... 224 13.4.1 To display the help text in case of a malfunction ..................225 13.4.2 Error codes: Overview ............................ 225 14 Disposal Installer reference guide EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 5
Piping diagram: Indoor unit ............................235 15.4 Wiring diagram: Outdoor unit ............................236 15.5 Wiring diagram: Indoor unit ............................241 16 Glossary 17 Field settings table EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Indicates a situation that could result in death or serious injury. WARNING: FLAMMABLE MATERIAL CAUTION Indicates a situation that could result in minor or moderate injury. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Improper installation or attachment of equipment or accessories could result in electrical shock, short-circuit, leaks, fire or other damage to the equipment. Only use accessories, optional equipment and spare parts made or approved by Daikin. WARNING Make sure installation, testing and applied materials comply with applicable legislation (on top of the instructions described in the Daikin documentation).
▪ In places where there is a risk of fire due to the leakage of flammable gases (example: thinner or gasoline), carbon fibre, ignitable dust. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
To avoid compressor breakdown, do NOT charge more than the specified amount of refrigerant. ▪ When the refrigerant system is to be opened, refrigerant MUST be treated according to the applicable legislation. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
If applicable. See the installation manual or installer reference guide of your application for more information. NOTICE Make sure water quality complies with EU directive 98/83 EC. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 12
Running the product in reversed phase can break the compressor and other parts. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Format: Paper (in the box of the indoor unit) + Digital files on http:// www.daikineurope.com/support-and-manuals/product-information/ Latest revisions of the supplied documentation may be available on the regional Daikin website or via your dealer. The original documentation is written in English. All other languages are translations. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G)
About the documentation Technical engineering data ▪ A subset of the latest technical data is available on the regional Daikin website (publicly accessible). ▪ The full set of latest technical data is available on the Daikin Business Portal (authentication required).
Page 15
Note: There is also an installer settings table in the user reference guide. This table has to be filled in by the installer and handed over to the user. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
To avoid injury, do NOT touch the air inlet or aluminium fins of the unit. Crane Keep the slings within the marked area to not damage the unit. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 17
After unpacking, carry the unit using the slings attached to the unit. See also: ▪ "To unpack the outdoor unit" [ 18] ▪ "To install the outdoor unit" [ 64] ±150 4× EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
About the box 3.2.2 To unpack the outdoor unit a, b Accessories EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Installation manual – Discharge grille NOTICE Unpacking. When you remove the top packaging/accessories, hold the box containing the discharge grille to prevent it from falling. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Handles at the back of the unit b Handles at the bottom of the unit. Carefully tilt the unit to the back so that the handles become visible. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Location Model identification Example: EP R A 14 DA V3 Code Explanation European hydro-split outdoor pair heat pump High water temperature – ambient zone 2 (see operation range) Refrigerant R32 EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Certain options might not be available in your country. 4.3.1 Possible combinations of indoor unit and outdoor unit Indoor unit Outdoor unit EPRA14 EPRA16 EPRA18 ETVH/X16 EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
To enable the power saving consumption control by digital inputs you must install the demand PCB. For installation instructions, see the installation manual of the demand PCB and addendum book for optional equipment. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 24
Use the system in various Smart Grid applications. For installation instructions, see the installation manual of the LAN adapter and the addendum book for optional equipment. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 25
For installation instructions, see the installation and operation manual of the Human Comfort Interface (HCI) as room thermostat. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Setting up the domestic hot water tank ▪ Setting up the energy metering ▪ Setting up the power consumption control ▪ Setting up an external temperature sensor EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Automatic. NOTICE An overpressure bypass valve can be integrated in the system. Keep in mind that this valve might not be shown on the illustrations. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
For your daily needs, you can use preset values and schedules. To deviate from your daily needs, you can temporarily overrule the preset values and schedules, or use the holiday mode. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 29
Code: [C-05] heating or cooling demand. Benefits ▪ Wireless. The Daikin external room thermostat is available in a wireless version. ▪ Efficiency. Although the external room thermostat only sends ON/OFF signals, it is specifically designed for the heat pump system. ▪...
Page 30
Benefits ▪ Cooling. The heat pump convector offers, besides heating capacity, also excellent cooling capacity. ▪ Efficiency. Optimal energy efficiency because of the interlink function. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 31
The shut-off valve Configuration Setting Value Unit temperature control: 1 (External room thermostat): Unit operation is decided by the ▪ #: [2.9] external thermostat. ▪ Code: [C-07] EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Setup A Main leaving water temperature zone B Room 1 C Room 2 a Dedicated Human Comfort Interface (BRC1HHDA used as room thermostat) EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 33
98] ▪ For each room, a shut-off valve (field supplied) is installed to avoid leaving water supply when there is no heating or cooling demand. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 34
▪ For more information about connecting the electrical wiring to the unit, see: "8.2 Connections to the outdoor unit" [ 91] "8.3 Connections to the indoor unit" [ 98] EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 35
Combination: Underfloor heating + Heat pump convectors – Multiple rooms Setup A Main leaving water temperature zone B Room 1 C Room 2 a External room thermostat b Heat pump convectors (+ controllers) EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Main zone = Zone with the lowest design temperature in heating, and the highest design temperature in cooling ▪ Additional zone = Zone with the highest design temperature in heating, and the lowest design temperature in cooling EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 37
▪ For more information about connecting the electrical wiring to the unit, see: "8.2 Connections to the outdoor unit" [ 91] "8.3 Connections to the indoor unit" [ 98] EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 38
Set to follow the thermo demand of the main zone. Shut-off valve If the main zone must be shut off during cooling mode to prevent condensation on the floor, set it accordingly. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
During heating operation of the auxiliary boiler, the auxiliary boiler operates to achieve the desired water temperature set via the auxiliary boiler controller. Setup ▪ Integrate the auxiliary boiler as follows: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 40
Make sure the auxiliary boiler and its integration in the system complies with applicable legislation. ▪ Daikin is NOT responsible for incorrect or unsafe situations in the auxiliary boiler system. ▪ Make sure the return water to the heat pump does NOT exceed 60°C. To do so: Set the desired water temperature via the auxiliary boiler controller to maximum 60°C.
Page 41
To prevent freeze-up of the water piping, the auxiliary gas boiler must have a fixed setpoint ≥55°C, or a weather-dependent setpoint ≥T (°C) –30 –25 –20 –15 –10 –5 (°C) Outdoor temperature Minimum weather-dependent setpoint for auxiliary gas boiler EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Example: If the DHW consumption of a family (4 persons) per day is as follows: ▪ 3 showers ▪ 1 bath ▪ 3 sink volumes Then the DHW consumption = (3×100 l)+(1×150 l)+(3×10 l)=480 l EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 43
EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
For more information, see "9 Configuration" [ 115]. ▪ You can program a schedule to control the DHW pump via the user interface. For more information, see the user reference guide. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
You can read out the energy data: For space heating For space cooling For domestic hot water production ▪ You can read out the energy data: Per month Per year EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
INFORMATION When measuring the electrical power consumption, make sure ALL power input of the system is covered by the electrical power meters. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Indoor unit (L e Outdoor unit (L f Backup heater (L f Indoor unit (L g Booster heater (L g Backup heater (L h Booster heater (L EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Single-phase outdoor unit with a three-phase backup heater: 58 0 58 0 1 5 0 1 5 0 A Outdoor unit B Indoor unit C DHW tank EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Permanent power limitation is useful to assure a maximum power or current input of the system. In some countries, legislation limits the maximum power consumption for space heating and DHW production. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
5.6.2 Power limitation activated by digital inputs Power limitation is also useful in combination with an energy management system. The power or current of the entire Daikin system is limited dynamically by digital inputs (maximum four steps). Each power limitation level is set via the user interface by limiting one of the following: ▪...
If the configuration is as follows: Power limitation level does NOT allow operation of backup heater (step 1). Then power consumption is limited as follows: Produced heat Consumed energy EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
You can connect one external temperature sensor. It measures the indoor or outdoor ambient temperature. We recommend to use an external temperature sensor in the following cases: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 53
To protect the outdoor unit, the internal sensor of the outdoor unit is always used. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Mind the spacing guidelines. See "15.1 Service space: Outdoor unit" [ 233]. NOTICE ▪ Do NOT stack the units on each other. ▪ Do NOT hang the unit on a ceiling. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 55
This is to prevent corrosion caused by high levels of salt in the air, which might shorten the life of the unit. Install the outdoor unit away from direct sea winds. Example: Behind the building. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 56
WARNING Make sure installation, servicing, maintenance and repair comply with instructions from Daikin and with applicable legislation (for example national gas regulation) and are executed only by authorised persons. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G)
Heating only models + conversion kit (EKHVCONV2) ▪ Mind the measurement guidelines: Maximum height difference between indoor unit and outdoor 10 m unit Maximum total water piping length 50 m EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Precise water piping length can be determined using the Hydronic Piping Calculation tool. The Hydronic Piping Calculation tool is part of the Heating Solutions Navigator which can be reached via https://professional.standbyme.daikin.eu. Please contact your dealer if you have no access to Heating Solutions Navigator.
3 Remove the transportation stays (2×), and dispose of them. 6.2.4 To close the outdoor unit NOTICE When closing the outdoor unit cover, make sure that the tightening torque does NOT exceed 4.1 N•m. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
NOTICE If you remove the user interface panel, also disconnect the cables from the back of the user interface panel to prevent damage. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 61
▪ When you need access to the high voltage switch box 2× 5 If you need access to the high voltage components, remove the high voltage switch box cover. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
2 Tilt the switch box to the front and lift it out of its hinges. 2× 3 Place the switch box lower on the unit. Use the 2 hinges located lower on the unit. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Check the strength and level of the installation ground so that the unit will not cause any operating vibration or noise. Fix the unit securely by means of foundation bolts in accordance with the foundation drawing. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Make sure not to cover the drain hole in the bottom plate of the unit. 6.3.4 To install the outdoor unit 1 Carry the unit by its slings, and put it onto the installation structure. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Install the unit on a base to make sure that there is proper drainage in order to avoid ice accumulation. ▪ Prepare a water drainage channel around the foundation to drain waste water away from the unit. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 66
O-ring (delivered as accessory) c Drain plug (delivered as accessory) d Hose (field supply) NOTICE O-ring. Make sure the O-ring is installed correctly to prevent leakage. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
4 Align and attach the left side. 5 Align and attach the middle part. 6 Align and attach the right side. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
67] ▪ "To remove the discharge grille, and put the grille in safety position" [ 68] 1 Remove the upper part of the discharge grille. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 69
4 Align the ball stud and hook on the grille with their counterparts on the unit. 5 Insert the hook. 6 Insert the ball stud. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
3 Slide the indoor unit into position. 4 Adjust the height of the leveling feet to compensate for floor irregularities. The maximum allowed deviation is 1°. ≤1° EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
4 Reattach the side panel. Ensure the water can flow through the drain tube. It is recommended to use a tundish to collect the water. Option 1: Through the left side panel 3× EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 72
Unit installation Option 2: Through the right side panel 3× EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Closed circuit. Use the indoor unit ONLY in a closed water system. Using the system in an open water system will lead to excessive corrosion. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 74
Drainage – Pressure relief valve. Connect the drain hose properly to the drain to avoid water dripping out of the unit. See "To connect the drain hose to the drain" [ 71]. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
7.1.3 To check the water volume and flow rate The indoor unit has an expansion vessel of 10 litre with a factory-set pre-pressure of 1 bar. To make sure that the unit operates properly: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 76
Use the following graph to determine the maximum water volume for the calculated pre-pressure. 200 220 A Pre-pressure (bar) B Maximum water volume (l) Water Water + glycol Example: Maximum water volume and expansion vessel pre-pressure EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 77
NOT be displayed on the user interface. In this case, the minimum flow rate can be checked by way of the pump test (check that the user interface does NOT display error 7H). EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Because the total water volume (250 l) is more than the default water volume (200 l), the pre-pressure must be decreased. ▪ The required pre-pressure is: Pg = (0.3+(H/10)) bar = (0.3+(0/10)) bar = 0.3 bar EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Deformation of the piping can cause malfunctioning of the unit. Outdoor unit 1 Connect the shut-off valve (with integrated filter) to the outdoor unit water inlet, using thread sealant. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 80
Space heating/cooling – Water IN (screw connection, 1") a2 Space heating/cooling – Water OUT (screw connection, 1") b1 DHW – Cold water IN (screw connection, 3/4") EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 81
If this is NOT working correctly, overpressure will deform the tank and water leakage may occur. To confirm good operation, regular maintenance is required. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Add glycol to the water. Glycol lowers the freezing point of the water. ▪ Install freeze protection valves. Freeze protection valves drain the water from the system before it can freeze. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 83
To prevent the system from freezing, more glycol is required. Add glycol according to the table below. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 84
To install freeze protection valves To protect the field piping against freezing, install the following parts: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
1 Open every hot water tap in turn to purge air from the system pipe work. 2 Open the cold water supply valve. 3 Close all water taps after all air is purged. 4 Check for water leaks. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
The Hydronic Piping Calculation tool is part of the Heating Solutions Navigator which can be reached via https://professional.standbyme.daikin.eu. Please contact your dealer if you have no access to Heating Solutions Navigator. This recommendation ensures good operation of the unit, however, local regulations may differ and shall be followed.
DANGER: RISK OF ELECTROCUTION WARNING ALWAYS use multicore cable for power supply cables. INFORMATION Also read the precautions and requirements in the "1 General safety precautions" [ 6]. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Stranded conductor wire b Round crimp-style terminal ▪ Use the following methods for installing wires: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Preferential kWh rate power supply 1 Power supply for outdoor unit 2 Power supply and interconnection cable to indoor unit 3 Power supply for backup heater EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
An excessive strip length may cause electrical shock or leakage 3 Insert the cables at the back of the unit, and route them through the factory- mounted cable sleeves into the switch box. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 92
▪ Connect the wires to the terminal block (make sure the numbers match with the numbers on the indoor unit) and the earth screw. ▪ Fix the cable with a cable tie. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 93
▪ Fix the cable with cable ties. Wires: (2+GND)×0.75 mm². Wiring must be double insulated. Maximum power allowed for drain tube heater = 115 W (0.5 A) — EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 94
▪ Connect the wires to the terminal block. ▪ Fix the cable with a cable tie. Wires: 3N+GND Maximum running current: Refer to name plate on unit. — EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 95
▪ Connect the wires to the terminal block (make sure the numbers match with the numbers on the indoor unit) and the earth screw. ▪ Fix the cable with a cable tie. Wires: (3+GND)×1.5 mm² — EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 96
▪ Fix the cable with cable ties. Wires: (2+GND)×0.75 mm². Wiring must be double insulated. Maximum power allowed for drain tube heater = 115 W (0.5 A) — EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
8.2.2 To reposition the air thermistor on the outdoor unit This procedure is only necessary in areas with low ambient temperatures. Required accessory (delivered with the unit): Thermistor fixture. Click EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Maximum running current: 100 mA For the main zone: ▪ [2.9] Control ▪ [2.A] Thermostat type For the additional zone: ▪ [3.A] Thermostat type ▪ [3.9] (read-only) Control EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 99
▪ Installation manual of the remote indoor sensor ▪ Addendum book for optional equipment Wires: 2×0.75 mm² [9.B.1]=2 (External sensor = Room) [1.7] Room sensor offset EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 100
To allow for energy buffering in the domestic hot settings water tank, on the user interface, make sure to set [9.2.1]=4 (Domestic hot water = Integrated). EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
In case of normal kWh rate power supply Interconnection cable Wires: (3+GND)×1.5 mm² (= main power supply) — 1 2 3 1 2 3 X11YB X11YA X11Y a Interconnection cable (=main power supply) EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 102
Interconnection cable (=main power supply) b Normal kWh rate power supply c Preferential power supply contact 3 Fix the cables with cable ties to the cable tie mountings. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
0.22 Ω 2 kW 3~ 230 V 5 A — 4 kW 3~ 230 V 10 A — 6 kW 3~ 230 V 15 A — 3 kW 3N~ 400 V 4 A — 6 kW 3N~ 400 V 9 A — 9 kW 3N~ 400 V 13 A — EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 104
Field wiring (see table below) Model (power supply) Connections to backup heater power supply *6V (6V: 1N~ 230 V) Q1DI 1N~, 50 Hz 230 V AC EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
For more information, see the installer reference guide. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
3 Fix the cable with cable ties to the cable tie mountings. 8.3.4 To connect the electricity meters Wires: 2 (per meter)×0.75 mm² Electricity meters: 12 V DC pulse detection (voltage supplied by PCB) [9.A] Energy metering EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
DHW pump output. Maximum load: 2 A (inrush), 230 V AC, 1 A (continuous) [9.2.2] DHW pump [9.2.3] DHW pump schedule 1 Open the following (see "To open the indoor unit" [ 60]): EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
2 User interface panel 3 Upper switch box cover 2 Connect the alarm output cable to the appropriate terminals as shown in the illustration below. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Heating only models + conversion kit (EKHVCONV2) Wires: (2+1)×0.75 mm² Maximum load: 0.3 A, 250 V AC — 1 Open the following (see "To open the indoor unit" [ 60]): EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
3 Fix the cable with cable ties to the cable tie mountings. 8.3.8 To connect the changeover to external heat source Wires: 2×0.75 mm² Maximum load: 0.3 A, 250 V AC Minimum load: 20 mA, 5 V DC [9.C] Bivalent EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
[9.9] Power consumption control. 1 Open the following (see "To open the indoor unit" [ 60]): 1 Top panel 2 User interface panel 3 Upper switch box cover EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
2 User interface panel 3 Upper switch box cover 2 Connect the safety thermostat (normally closed) cable to the appropriate terminals as shown in the illustration below. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
8.4 After connecting the electrical wiring to the indoor unit To prevent water ingress to the switch box, seal the low voltage wiring intake using the sealing tape (delivered as accessory). EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 114
Electrical installation Without low voltage cables With low voltage cables EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
First time – Configuration wizard. When you turn ON the user interface for the first time (via the unit), the configuration wizard starts to help you configure the system. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Confirm the pin code and proceed. Installer pin code The Installer pin code is 5678. Additional menu items and installer settings are now available. Installer 5678 EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 117
4 Turn the left dial to select the second part of the setting 01 15 5 Turn the right dial to modify the value from 15 to 20. 01 20 EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Comfort setpoint [5.2] Eco setpoint [5.3] Reheat setpoint [5.4] Hysteresis [5.9] and [5.A] 9.3 Possible screens 9.3.1 Possible screens: Overview The most common screens are as follows: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
26 Feb 2019 22:19 Possible actions on this screen Go through the list of the main menu. Go to the main menu screen. Enable/disable breadcrumbs. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 121
Outdoor unit Indoor unit / domestic hot water tank Floor-standing indoor unit with integrated tank Wall-mounted indoor unit Wall-mounted indoor unit with separated tank Water pressure EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 122
"To display the help text in case of a malfunction" [ 225] for more information. If the corresponding operation (for example: space heating) is not active, the circle is greyed out. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Displays data and information about the Information indoor unit. Installer settings Restriction: Only for the installer. Gives access to advanced settings. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
[2] Main zone screen °C °C – – Room Main zone [3] Additional zone screen [5] Tank temperature screen °C °C – – Tank Additional zone EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Confirm changes and proceed. 9.3.7 Schedule screen: Example This example shows how to set a room temperature schedule in heating mode for the main zone. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 126
To clear the content of the week schedule 1 Select the name of the current schedule. User defined 1 2 Select Delete. Delete Rename Select 3 Select OK to confirm. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 127
In this example, Monday is the first day you programmed. Thus, the last programmed action is valid up to the first action of next Monday. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 128
5 Repeat this action for all other weekdays. — User defined 1 To program the schedule for Saturday and copy it to Sunday 1 Select Saturday. 2 Select Edit. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 129
The schedule name can contain up to 15 characters. 5 Confirm the new name. INFORMATION Not all schedules can be renamed. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Examples Weather-dependent curve when slope is selected: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 132
The icon corresponds to the heat emitter for that zone: ▪ : Underfloor heating ▪ : Fan coil unit ▪ : Radiator ▪ : Domestic hot water tank EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Go to … Main zone – Heating [2.5] Main zone > Heating WD curve Main zone – Cooling [2.6] Main zone > Cooling WD curve EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
No: Room temperature is directly controlled by the user. ▪ Yes: Room temperature is controlled by a schedule and can be modified by the user. Heating schedule Applicable for all models. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 136
Antifrost function via the backup heater. If the backup heater is not allowed for room frost protection during a U4 error, the room Antifrost setting MUST be disabled. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 137
Room frost protection is guaranteed by the normal logic. ▪ The external room thermostat is "Thermo ON" In case of 2 leaving water temperature zones: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 138
NOTICE When adjusting the room temperature ranges, all desired room temperatures are also adjusted to guarantee they are between the limits. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Only applicable if the external room sensor option is installed and configured. ▪ –5°C~5°C, step 0.5°C 9.5.3 Main zone Overview The following items are listed in the submenu: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 140
Define a heating temperature schedule for the main zone via [2.2] Heating schedule. "Schedule screen: Example" [ 125]. Cooling schedule Define a cooling temperature schedule for the main zone via [2.3] Cooling schedule. "Schedule screen: Example" [ 125]. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 141
10°C. Heating WD curve Set weather-dependent heating for the main zone (if [2.4]=1 or 2): EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 142
Note: This value should be lower than [1‑02] as for high outdoor temperatures less warm water is required. Cooling WD curve Set weather-dependent cooling for the main zone (if [2.4]=2): EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 143
It is important to set Emitter type correctly and in accordance with your system layout. The target delta T for the main zone depends on it. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 144
Example underfloor heating: 40–5/2=37.5°C To compensate, you can: ▪ Increase the weather-dependent curve desired temperatures [2.5]. ▪ Enable leaving water temperature modulation and increase the maximum modulation [2.C]. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 145
Heating maximum: ▪ [2‑0C]=2 (emitter type main zone = radiator) 37°C~70°C ▪ Else: 37°C~55°C [2.8.3] [9-03] Cooling minimum: ▪ 5°C~18°C [2.8.4] [9-02] Cooling maximum: ▪ 18°C~22°C EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 146
Leaving water temperature: Delta T In heating for the main zone, the target delta T (temperature difference) depends on the selected emitter type for the main zone. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 147
Additionally, also the desired leaving water temperature must be configured: if Modulation is enabled, the unit automatically calculates the desired leaving water temperature. These calculations are based on: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 148
1 leaving water temperature zone, connect the shut-off valve to the heating/cooling output. The shut off valve for the main leaving water temperature zone can close under these circumstances: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
130] and "Slope-offset curve" [ 131]. Code Description [2.E] ▪ 2-points ▪ Slope-Offset 9.5.4 Additional zone Overview The following items are listed in the submenu: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 150
125]. Setpoint mode The setpoint mode of the additional zone can be independently set from the setpoint mode of the main zone. "Setpoint mode" [ 141]. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 151
Also see "Main zone" [ 139]. Code Description [2.E] ▪ 2-points ▪ Slope-Offset Heating WD curve Set weather-dependent heating for the additional zone (if [3.4]=1 or 2): EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 152
Note: This value should be lower than [0‑01] as for high outdoor temperatures less warm water is required. Cooling WD curve Set weather-dependent cooling for the additional zone (if [3.4]=2): EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 153
[9‑05]~[9‑06] [1‑0C] 0: Underfloor Maximum 55°C Variable (see [3.B.1]) heating 1: Fancoil unit Maximum 55°C Variable (see [3.B.1]) 2: Radiator Maximum 70°C Fixed 10°C EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 154
(X2M/35a) ▪ 2: 2 contacts. Connected to 2 digital inputs (X2M/34a and X2M/35a) Leaving water temperature: Delta T For more information, see "Main zone" [ 139]. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
To tell the system which space operation to use, you can: You can… Location Check which space operation mode is currently used. Home screen EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 156
2 Select a month. 3 For each month, select an option: ▪ Reversible: Not restricted ▪ Heating only: Restricted ▪ Cooling only: Restricted 4 Confirm the changes. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 157
Example: A unit is configured as following: ▪ Desired room temperature in heating mode: 22°C ▪ Desired room temperature in cooling mode: 24°C ▪ Hysteresis value: 1°C EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 158
INFORMATION Mixing station. If your system layout contains 2 LWT zones, you need to install a mixing station in front of the main LWT zone. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 159
Make sure you set the emitter types for the main zone [2.7] and for the additional zone [3.7] correctly in accordance with the connected emitter. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 160
Sample is ONLY available in leaving water temperature control. a Space heating/cooling control b Off c On d LWT temperature e Actual f Desired g Pump operation EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 161
With this limitation range, delta T is possible and the comfort is guaranteed. The maximum values depend on the unit type: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 162
Use this setting to compensate for possible heat losses of the building due to the evaporation of melted ice or snow. (e.g. in cold region countries). EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Room frost protection [1.4] prevents the room from getting too cold. For more information about room frost protection, see "Room" [ 135]. 9.5.6 Tank Overview The following items are listed in the submenu: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 164
When powerful operation is active, the risk of space heating/cooling and capacity shortage comfort problems is significant. In case of frequent domestic hot water operation, frequent and long space heating/cooling interruptions will happen. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 165
The domestic hot water can be prepared in 3 different ways. They differ from each other by the way the desired tank temperature is set and how the unit acts upon it. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 167
The maximum temperature that users can select for the domestic hot water. You can use this setting to limit the temperatures at the hot water taps. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
The maximum heat pump temperature depends on the ambient temperature. For more information, see the operation range. 9.5.7 User settings Overview The following items are listed in the submenu: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 171
To configure the holiday 1 Activate the holiday mode. — ▪ Go to [7.3.1]: User settings > Holiday > Activation. 7.3.1 Activation From Till ▪ Select On. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 172
Go to [7.4.3] Level and select the applicable quiet mode level. Example: Most quiet. Result: The unit always runs in the selected quiet mode level. The user cannot change this. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 173
INFORMATION Price value ranging from 0.00~990 valuta/kWh (with 2 significant values). INFORMATION If no schedule is set, the Electricity price for High is taken into account. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 174
Renewable heat incentive per kWh Calculation of the gas price Gas price=Actual gas price+(Incentive/kWh×0.9) Gas price=4.08+(5×0.9) Gas price=8.58 Calculation of the electricity price Electricity price=Actual electricity price+Incentive/kWh EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
In menu… You can read out… [8.1] Energy data Produced energy, consumed electricity, and consumed gas [8.2] Malfunction history Malfunction history [8.3] Dealer information Contact/helpdesk number EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
[9.C] Bivalent [9.D] Alarm output [9.E] Auto restart [9.F] Power saving function [9.G] Disable protections [9.H] Forced defrost [9.I] Overview field settings [9.N] Export MMI settings EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 177
When turned on, the pump runs and makes sure hot water is instantly available at the tap. To save energy, only turn on the pump during periods of the day when instant hot water is necessary. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 178
[6‑03]+[6‑04]. INFORMATION If [4‑0A]=3 and emergency mode is active, the power usage of the backup heater is maximal and equal to 2×[6‑03]+[6‑04]. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 179
Only for systems with integrated domestic hot water tank: If the storage temperature setpoint is higher than 50°C, Daikin recommends NOT to disable the backup heater second step because it will have a big impact on the required time for the unit to heat up the domestic hot water tank.
Page 180
NOT confirm emergency operation. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 181
[5‑01] Equilibrium temperature and [5‑03] Space heating priority temperature are related to backup heater. So, you must set [5‑03] equal or a few degrees higher than [5‑01]. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 182
[8-04]. Range: 0~10 hours Remark: The minimum time is 0.5 hours even when the selected value is 0. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 183
The preferential kWh rate power supply contact is connected to the same terminals (X5M/9+10) as the safety thermostat. Thus, the system can have EITHER preferential kWh rate power supply OR a safety thermostat. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 184
Do NOT use 1 or 3. Setting [D-00] to 1 or 3 when [D-01] is set to 1 or 2 will reset [D-00] back to 0, as the system does not have a booster heater. Only set [D-00] to the values in the table below: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 185
[5-09] Limit: Only applicable in case of full time power limitation mode. 0 kW~20 kW Limits when [9.9.1]=Inputs and [9.9.2]=kW: Code Description [9.9.9] [5-09] Limit 1: 0 kW~20 kW EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 186
(BBR16 activation and BBR16 power limit). After 2 weeks, the unit freezes these settings. Note: This is different from the permanent power limitation, which is always changeable. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 188
The outdoor temperature is averaged over the selected time period. Code Description [9.B.3] [1-0A] Averaging time: ▪ 0: No averaging ▪ 1: 12 hours ▪ 2: 24 hours ▪ 3: 48 hours ▪ 4: 72 hours EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 189
[C‑03] or above [C‑03]+[C‑04]. calc 3°C Fixed hysteresis to prevent too much switching between heat pump system and auxiliary boiler a Auxiliary boiler active b Auxiliary boiler inactive EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 190
Make sure to use the same units of measurement for the electricity price and gas price (example: both c€/kWh). 2 Determine the value of [C‑03] using the graph. For an example, see the table legend. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 191
User settings > Electricity price > High [7.5.2] User settings > Electricity price > Medium [7.5.3] User settings > Electricity price > [7.6] User settings > Gas price EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 192
The final decision to allow power interruption of the outdoor unit during standstill depends on the ambient temperature, compressor conditions and minimum internal timers. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 193
[9.I]. See "To modify an overview setting" [ 117]. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
User profile Operation [A.3] Air purge [A.4] UFH screed dryout About commissioning See: "10 Commissioning" [ 199] 9.5.11 Operation Overview The following items are listed in the submenu: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
[D.4] Device info About the WLAN adapter The wireless LAN adapter connects the heat pump system to the internet. The user can then control the heat pump system via the Daikin Residential Controller app. This needs the following components: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G)
Page 196
See: http://www.onlinecontroller.daikineurope.com/ Configuration To configure the Daikin Residential Controller app, follow the in-app instructions. While doing this, the following actions and information are needed on the user interface of the indoor unit: Mode: Turn AP mode ON (= WLAN adapter active as access point) or OFF.
(**) Only accessible by installer (***) Only applicable when WLAN adapter is installed INFORMATION Depending on the selected installer settings and unit type, settings will be visible/ invisible. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Solar kit settings are shown but are NOT applicable for this unit. Settings shall NOT be used or changed. INFORMATION Depending on the selected installer settings and unit type, settings will be visible/ invisible. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
10 Commissioning NOTICE General commissioning checklist. Next to the commissioning instructions in this chapter, a general commissioning checklist is also available on the Daikin Business Portal (authentication required). The general commissioning checklist is complementary to the instructions in this chapter and can be used as a guideline and reporting template during the commissioning and hand-over to the user.
There are NO damaged components or squeezed pipes on the inside of the indoor and outdoor units. Backup heater circuit breaker F1B (field supply) is turned ON. The correct pipe size is installed and the pipes are properly insulated. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
— reach the minimum required flow rate + 2 l/min. During pump test run, the unit can operate below the minimum required flow rate. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
3 In the menu, set Type = Manual. 4 Select Start air purge. 5 Select OK to confirm. Result: The air purge starts. It stops automatically when ready. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
"To change — the user permission level" [ 116]. 2 Go to [A.1]: Commissioning > Operation test run. 3 Select a test from the list. Example: Heating. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
1 In the menu, go to Stop test run. 2 Select OK to confirm. Possible actuator test runs ▪ Backup heater 1 test ▪ Backup heater 2 test ▪ Pump test EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
1 the duration in hours, up to 72 hours, 2 the desired leaving water temperature, up to 55°C. Example: 24h (1) 36h (2) 35°C (2) 25°C (1) T Desired leaving water temperature (15~55°C) EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 206
[D‑01]=0 ▪ [4‑08]=0 ▪ [4‑01]≠1 Steps Conditions: An underfloor heating screed dryout schedule has been programmed. "To program an underfloor heating screed dryout schedule" [ 205]. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 207
When the program is stopped due to an error, an operation switch-off, or a power failure, you can read out the underfloor heating screed dryout status: 1 Go to [A.4.3]: Commissioning > UFH screed dryout > Status EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 208
If the UFH screed dryout program was stopped due to a power failure and the power resumes, the program will automatically restart the last implemented step. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Show the user what to do for the maintenance of the unit. ▪ Explain the user about energy saving tips as described in the operation manual. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Before performing any maintenance or service work, touch a metal part of the unit in order to eliminate static electricity and to protect the PCB. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Switch box ▪ Descaling ▪ Chemical disinfection 12.3.4 Yearly maintenance indoor unit: instructions Water pressure Keep water pressure above 1 bar. If it is lower, add water. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 212
"To install the water filter" [ 216] Water pressure relief valve Open the valve and check if it operates correctly. The water may be very hot! Checkpoints are: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 213
For this reason, descaling of the heat exchanger may be required at certain intervals. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
▪ "To remove the water filter" [ 215] ▪ "To clean the water filter in case of trouble" [ 215] ▪ "To install the water filter" [ 216] EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Opening the magnetic filter/dirt separator is ONLY required in case of severe issues. Preferably this action is never to be done during the complete lifetime of the magnetic filter/dirt separator. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Check the condition of the O-rings and replace if needed. Apply water to the O-rings before installation. 1 Install the water filter in the correct location. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 217
Make sure to open the valve (if equipped) towards the expansion vessel, otherwise the overpressure will be generated. 5 Open the stop valves and add water to the water circuit if needed. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
If you are unable to find the cause of the problem, call your dealer. DANGER: RISK OF ELECTROCUTION EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Make sure that the water volume in the too low installation is above the minimum required value (see "To check the water volume and flow rate" [ 75]). EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
We recommend to purge air with the air purge function of the unit (to be performed by the installer). If you purge air from the heat emitters or collectors, mind the following: EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Purge air manually (see "To perform a manual air purge" [ 202]) or use the automatic air purge function (see "To perform an automatic air purge" [ 203]). EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
▪ If the water keeps running out of the unit, close both the water inlet and outlet shut-off valves first and then contact your dealer. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
INFORMATION See the service manual for: ▪ The complete list of error codes ▪ A more detailed troubleshooting guideline for each error EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Overheating mixed water circuit (thermostat) 8H-03 Overheating water circuit (thermostat) A1-00 Zero cross detection problem A5-00 OU: High pressure peak cut / freeze protection problem EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 226
Malfunction of compressor overload protection H6-00 OU: Malfunction of position detection sensor H8-00 OU: Malfunction of compressor input (CT) system H9-00 OU: Malfunction of outdoor air thermistor EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 227
Malfunction by reverse phase/open-phase U2-00 OU: Defect of power supply voltage U3-00 Underfloor heating screed dryout function not completed correctly U4-00 Indoor/outdoor unit communication problem EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 228
If an U8‑04 error occurs, the error can be reset after a successful update of the software. If the software is not successfully updated then you must make sure that your USB device has the FAT32 format. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 229
Troubleshooting INFORMATION The user interface will display how to reset an error code. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
See: ▪ "To install the discharge grille" [ 67] ▪ "To remove the discharge grille, and put the grille in safety position" [ 68] EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 231
3 Turn the EEV magnet clockwise to the fully open position of the valve. If you are not sure about what the open position is, turn the valve in its middle position so that refrigerant can pass. EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Technical data 15 Technical data A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of latest technical data is available on the Daikin Business Portal (authentication required). In this chapter 15.1...
Right side view See note *** See note *** Notes: Symbols: Live Neutral Protective earth Noiseless earth Field wiring Option Terminal strip Terminal Connector Connection EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 237
Light-emitting diode (service monitor is orange) HAP (A1P) Light-emitting diode (service monitor is green) K1R (A1P) Magnetic relay (Y1S) K1R (A4P) Magnetic relay (E1HHEX~E3HHEX) K2R (A1P) Magnetic relay (Y2S) EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Safety thermostat Safety thermostat Main LWT Main leaving water temperature On/OFF thermostat (wired) On/OFF thermostat (wired) On/OFF thermostat (wireless) On/OFF thermostat (wireless) Ext. thermistor External thermistor EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 242
# 2-way valve for cooling mode PC (A15P) * Power circuit PHC1 (A4P) * Optocoupler input circuit Thermal protector backup heater # Safety thermostat Q*DI # Earth leakage circuit breaker EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 243
Only for remote user interface HCI Only for the dedicated Human Comfort Interface (BRC1HHDA used as room thermostat) Only for WLAN adapter Only for WLAN adapter SWB1 Switch box EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 244
(8) External On/OFF thermostats and heat pump convector heat pump convector Additional LWT zone Additional leaving water temperature zone Main LWT zone Main leaving water temperature zone EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 245
Only for heat pump convector Only for wired On/OFF thermostat Only for wired On/OFF thermostat Only for wireless On/OFF thermostat Only for wireless On/OFF thermostat EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Page 246
A20P: J2 2 core 2×0.75 communication A11P: X9: 1-2-3 X5M: 11-12 A14P: P1-P2 user interface communication 2 core 2×0.75 A13P: P1-P2 LAN adapter communication 4D124705A EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G) Installer reference guide Daikin Altherma 3 H HT F 4P587502-1B – 2020.12...
Optional equipment Equipment made or approved by Daikin that can be combined with the product according to the instructions in the accompanying documentation. Field supply Equipment NOT made by Daikin that can be combined with the product according to the instructions in the accompanying documentation.
Page 249
2/11 Field settings table Installer setting at variance with default value Breadcrumb Field code Setting name Range, step Date Official Value Default value Room └─ Antifrost 1.4.1 [2-06] Activation 0: Disabled 1: Enabled 1.4.2 [2-05] Room setpoint 4~16°C, step: 1°C 8°C └─...
Page 250
3/11 Field settings table Installer setting at variance with default value Breadcrumb Field code Setting name Range, step Date Official Value Default value Setpoint mode 0: Fixed 1: WD heating, fixed cooling 2: Weather dependent └─ Heating WD curve [0-00] Leaving water value for high ambient temp.
Page 251
4/11 Field settings table Installer setting at variance with default value Breadcrumb Field code Setting name Range, step Date Official Value Default value [6-0C] Reheat setpoint 30~min(50, [6-0E])°C, step: 1°C 45°C [6-0D] Heat up mode 0: Reheat only 1: Reheat + sched. 2: Scheduled only └─...
Page 252
5/11 Field settings table Installer setting at variance with default value Breadcrumb Field code Setting name Range, step Date Official Value Default value 9.1.4.2 [4-0A] Configuration 0: 1 1: 1/1+2 (*1) (*2) 2: 1/2 3: 1/2 + 1/1+2 in emergency 9.1.4.3 [6-03] Capacity step 1...
Page 253
6/11 Field settings table Installer setting at variance with default value Breadcrumb Field code Setting name Range, step Date Official Value Default value 9.1.B.3 [6-0B] Eco setpoint 30~min(50, [6-0E])°C, step: 1°C 45°C 9.1.B.4 [6-0C] Reheat setpoint 30~min(50, [6-0E])°C, step: 1°C 45°C 9.1.B.5 [6-08]...
Page 254
7/11 Field settings table Installer setting at variance with default value Breadcrumb Field code Setting name Range, step Date Official Value Default value 9.9.7 [5-08] Limit 4 0~50 A, step: 1 A 50 A 9.9.8 [5-09] Limit 0~20 kW, step: 0,5 kW 20 kW 9.9.9 [5-09]...
Page 255
8/11 Field settings table Installer setting at variance with default value Breadcrumb Field code Setting name Range, step Date Official Value Default value [1-00] Low ambient temp. for LWT main zone heating WD curve. -40~5°C, step: 1°C -15°C [1-01] High ambient temp. for LWT main zone heating WD curve. 10~25°C, step: 1°C 15°C [1-02]...
Page 256
9/11 Field settings table Installer setting at variance with default value Breadcrumb Field code Setting name Range, step Date Official Value Default value [3-09] What is the minimum desired room temperature in cooling? 15~25°C, step: 0,5°C 15°C [4-00] What is the BUH operation mode? 0: Disabled 1: Enabled 2: Only DHW...
Page 257
10/11 Field settings table Installer setting at variance with default value Breadcrumb Field code Setting name Range, step Date Official Value Default value [7-00] Domestic hot water booster heater overshoot temperature. 0~4°C, step: 1°C 0°C [7-01] Domestic hot water booster heater hysteresis. 2~40°C, step: 1°C 2°C [7-02]...
Page 258
11/11 Field settings table Installer setting at variance with default value Breadcrumb Field code Setting name Range, step Date Official Value Default value [C-0C] [C-0D] [C-0E] [D-00] Which heaters are permitted if prefer. kWh rate PS is cut? 0: None 1: BSH only 2: BUH only 3: All heaters...
Page 260
4P587502-1B 2020.12 Verantwortung für Energie und Umwelt...