8
|
Configuration
Installer reference guide
136
#
Code
N/A
[9‑0D]
The maximum values depend on the unit type:
[9-0D]=0
a (kPa)
[9-0D]=6
a (kPa)
[9-0D]=8
a (kPa)
a External static pressure
b Water flow rate
Pump speed limitation
0: No limitation.
1~4: General limitation. There is limitation in all
conditions. The required delta  T control and
comfort are NOT guaranteed.
5~8 (default: 6): Limitation when no actuators.
When there is no heating/cooling output, the
pump speed limitation is applicable. When
there is heating/cooling output, the pump
speed is only determined by delta T in relation
to the required capacity. With this limitation
range, delta T is possible and the comfort is
guaranteed.
[9-0D]=5
a (kPa)
b (l/min)
[9-0D]=7
a (kPa)
b (l/min)
b (l/min)
Description
b (l/min)
b (l/min)
CHYHBH05+08AF + EHYKOMB33A
Daikin Altherma R Hybrid
4P471761-1E – 2020.10