12
|
Maintenance and service
Installer reference guide
172
4 Fit the gas connection below the gas valve.
5 Fit the connector to the fan and the ignition unit to the gas valve.
6 Fit the condensate drain by sliding on the exchanger outlet stump with the
condensate trap connection still in front of the base tray.
a
a Base tray
7 Turn the condensate drain to the left and push it downwards into the
condensate trap connection. Make sure in doing this that the back of the
condensate drain pan comes to rest on the lug of the back of the base tray.
8 Fill the condensate trap with water and fit it to the connection below the
condensate drain pan.
9 Slide the flue pipe, turning it counterclockwise, with the top around the flue
adapter into the top cover.
10 Insert the bottom into the condensate drain pan and tighten the coupling nut
clockwise.
11 Open the gas tap and check the gas connections below the gas valve and on
the mounting bracket for leakage.
12 Check the space heating and the water pipes for leakages.
13 Turn on the main power supply.