Code
[A.4.6]
N/A
[A.4.7]
[0-0E]
[0-0D]
[0-0C]
[0-0B]
Timers for simultaneous request space and domestic hot water operation
When the unit starts heating the domestic hot water tank, it continuous until the
setpoint has been reached. However, if it takes too long (decided by the unit), the
unit will balance between heating of the domestic hot water tank and space
heating.
Disinfection
Applies only to installations with a domestic hot water tank.
The disinfection function disinfects the domestic hot water tank by periodically
heating the domestic hot water to a specific temperature.
Description
Desired temperature mode:
Fixed (default): disabled. All desired tank
temperature are NOT weather dependent.
dep.: enabled. In scheduled or
Weather
scheduled+reheat mode, the storage comfort
temperature is weather dependent. Storage
economic and reheat temperatures are NOT
weather dependent. In reheat mode, the
desired
tank
temperature
dependent.
Note: When the displayed tank temperature is
weather dependent, it cannot be adjusted on
the user interface.
Weather-dependent curve
T
DHW
[0-0C]
[0-0B]
T
a
[0-0E]
[0-0D]
T
: The desired tank temperature.
DHW
T
:
The
(averaged)
a
temperature
[0-0E]: low outdoor ambient temperature: –
40°C~5°C (default: –10°C)
[0-0D]: high outdoor ambient temperature:
10°C~25°C (default: 15°C)
[0-0C]: desired tank temperature when the
outdoor temperature equals or drops below
the low ambient temperature: 45°C~[6‑0E]°C
(default: 60°C)
[0-0B]: desired tank temperature when the
outdoor temperature equals or rises above the
high ambient temperature: 35°C~[6‑0E]°C
(default: 55°C)
is
weather
outdoor
ambient
CHYHBH05+08AF + EHYKOMB33A