Trouble
No fluid out of the gun.
Pattern width narrows
during reversing phase
of pump
Aircap becomes dirty
frequently
Fluid seeping from the air
holes of the aircap
Fluid leak at the packing
Fluid leak at the front
part of the gun, trigger
released
Air leak at the valve
Permanent air leak at
the gun aircap when the
trigger is released
Cause
Clogged nozzle
Air trapped in the fluid
circuit
Viscosity too high
Too much atomizing air
Defective tip seal
Tip loose
Packing is worn
Impurities in the paint
Needle worn or/and
nozzle worn
Valve worn
Friction on the needle
Valve worn
16
Solution
Cut the pressure on the
pump. Depressurize the
hoses.
Remove and clean the
nozzle with solvent by means
of the brush.
Check the seal condition.
Check connections and
suction hose quality.
Reduce viscosity.
Reduce air pressure.
Replace it.
Tighten it.
Tighten up the packing
holder without blocking the
needle.
If there is still a leak, replace
the packing and the needle.
Trigger the gun 3 or 4 times.
Replace needle and nozzle.
Change the valve.
Remove the trigger and
check the needle.
Replace the valve.