Download Print this page
SAMES KREMLIN FPRO G Troubleshooting Manual

SAMES KREMLIN FPRO G Troubleshooting Manual

Hide thumbs Also See for FPRO G:

Advertisement

Quick Links

FPRO G / GSP
DIAGNOSTIC / TROUBLESHOOTING
Diagnostic Help / Troubleshooting Guide
Topic
The defect comes from the head - Loosen the ring slightly
and rotate the head half a turn. If the defect is reversed,
one of the side vents is blocked or deformed.
Bean-shaped
Then clean the gun head with solvent and unclog the
spray
vents with a spray of compressed air. If this does not
reverse, the nozzle is probably damaged.
This deformation is due to a defect in the central spray. It
is necessary to clean the head as described above and
the nozzle. Also check:
Deported
spray
The pressure of the air sprays at the vents is too high for the
paint flow:
Cutted
spray
Default inverse of the previous one:
Spray loaded
in the center
The gun is machine-gunned. The phenomenon is caused
by air entering the paint circuit:
Jerky product
spray
If the phenomenon persists, disassemble the nozzle and
clean it.
Explanation
The head is well centered on the nozzle,
The nozzle is not too big (needle and nozzle must be
adapted), you work with a sufficient needlen opening,
With an almost closed needle, the product supply to
the spray is not regular in all directions.
Reduce air at the vents by closing the adjustment
needle. The spray is narrower.
Increase paint flow.
Either the paint flow rate is excessive for the adopted
spraying air pressure - You should increase the
spraying air pressure and reduce the paint flow rate.
Either the paint is too thick - You must then dilute it.
The container containing the paint may be empty -
Refill with paint.
The nozzle is not tightened properly and does not fit
properly on its seat - Tighten the nozzle.
Check the nozzle seat and cone for damage,
reassemble and secure the nozzle.
Check that the paint is fluid and homogeneous
enough to be vacuumed.
Visual

Advertisement

loading

Summary of Contents for SAMES KREMLIN FPRO G

  • Page 1 FPRO G / GSP DIAGNOSTIC / TROUBLESHOOTING Diagnostic Help / Troubleshooting Guide Topic Explanation Visual The defect comes from the head - Loosen the ring slightly and rotate the head half a turn. If the defect is reversed, one of the side vents is blocked or deformed.
  • Page 2 PLEASE NOTE: Before any action is taken on the gun, please shut off the compressed air supply and depressurize the systems by triggering the gun. LT 999-600-455 ©2021 SAMES KREMLIN Inc. reserves the right to change without notice characteristics and services offered as well as equipment and attachments of these.

This manual is also suitable for:

Fpro gsp