2. After installation and wiring have been completed, RE-INSTALL the lock cover through the
lock chassis using the two (2) phillips screws.

Performing Magnalock Maintenance

1. PERFORM the following to complete a visual inspection.
a. INSPECT the rubber washers for elasticity and proper pivoting; and TIGHTEN, as
required.
b. INSPECT for build-up of debris on the Magnalock and strike armature.
c. INSPECT for rust on the Magnalock and strike plate armature; CLEAN, as required.

Using Proper Cleaning Methods

1. APPLY rubbing alcohol onto a clean cloth and thoroughly WIPE DOWN the Magnalock and
strike plate armature.
NOTE 1: Cleaning once a year is recommended.
NOTE 2: Petroleum-based products should never be used for cleaning.
NOTE 3: Steel wool-based scrub pads or sandpaper should never be used for cleaning.
2. CLEAN every three to six months where rusting occurs.
3. USE a plastic dishwashing scrub pad to aid in the removal of rust.