Assa Abloy Securitron Magnalock M670BD Series Installation Instructions Manual page 7

Table of Contents

Advertisement

Component Label
Component Name
Jumper 4:
JP4
Door Position
(available on
Mode Select
M680 models
A 3-pin jumper that
only)
controls the output
setting for the Door
Position Switch (DPS)
in Terminal Block J1
Position 1 & 2.
J1 (M670)
Terminal Block 1
Position 1 & 2:
Input Power
Position 3 & 4:
Tamper Indication
J1 (M680)
Terminal Block 1
Position 1 & 2:
Door Position Switch
Position 3 & 4:
Input Power
Position 5 & 6:
Tamper Indication
Position 7 & 8:
BondSTAT
Selection
(NC) Normally Closed
Circuit Closed when Door
is Closed (default setting)
(NO) Normally Open
Circuit Open when Door is
Closed
(M670 has a 4-position terminal block)
Terminal positions 1 & 2 provide a connection point for
positive (+) and negative (-) 12 and 24 VDC power
connection.
Position 1 = (+) Positive
Position 2 = (-) Negative
Terminal positions 3 & 4 of the terminal block provide
connection for tamper sensing. Signal continuity is
disrupted whenever the cover is removed.
(M680 has an 8-position terminal block)
Terminal positions 1 & 2 provide a set of contacts of
which state change is determined by Jumper 4 (JP4)
based on the strike plate's proximity to the lock face.
Terminal positions 3 & 4 provide a connection point for
positive (+) and negative (-) 12 and 24 VDC power
connection.
Position 3 = (+) Positive
Position 4 = (-) Negative
Terminal positions 5 & 6 provide connection for tamper
sensing. Signal continuity is disrupted whenever the
cover is removed.
Terminal positions 7 & 8 provide a set of contacts of
which state change is determined by Jumper 3 (JP3)
based on the strike plate's magnetic bond to the lock
face under power.
Page 7
Position
PN# 500-10550
Rev. D, 12/14