Table 1. Component Label, Name, Selection, and Position
Component Label
Component Name
SW3
DIP Switch SW3.1:
LED Enable
Position 1 setting of
the DIP switch enables
or disables the display
of the LED for lock
(M670 has a
status.
2-position DIP)
SW3
DIP Switch SW3.2:
LED Color Select
Position 2 setting of
the DIP switch controls
the color of the LED
output. Output options
are red or green.
SW3
DIP Switch SW3.3,
SW3.4 and SW3.5:
Auto Relock Timer
Enable and Delay
Selection
The Auto Relock
Delay Timer is
(Auto Relock
disabled by default.
Timer available on
The delay can be
M680 models
enabled by setting the
only)
position 3 switch of
SW3 to ON, and then
selecting a time delay
with Position 4 and
Position 5 of SW3.
Jumper 3:
JP3
BondSTAT
(available on
Mode Select
M680 models
A 3-pin jumper that
only)
controls the output
setting for the
BondSTAT in Terminal
Block J1 Position 7 &
8.
Selection
ON = LED ENABLED
OFF = LED DISABLED
(default setting)
ON = SECURE = RED
OFF = SECURE = GREEN
(default setting)
DISABLE Delay Timer
ENABLE Delay Timer
5 second delay
10 second delay
20 second delay
30 second delay
(NC) Normally Closed
Circuit Closed when Bond
is secure (default setting)
(NO) Normally Open
Circuit Open when Bond is
secure
Page 6
Position
Position 1 ON (default)
Position 1 OFF
Position 2 ON
Position 2 OFF (default)
Position 3 OFF (default)
Position 3 ON
Position 4 OFF
Position 5 OFF
Position 4 OFF
Position 5 ON
Position 4 ON
Position 5 OFF
Position 4 ON
Position 5 ON
PN# 500-10550
Rev. D, 12/14