Table of Contents

Advertisement

1.7 Safety Policy

In order to meet the safety requirements of EN62368-1:2014 standard for Audio/Video, information and communication technology equipment, the SBC-C31 Module
shall be:
used exclusively inside a fire enclosure made of non-combustible material or V-1 material (the fire enclosure is not necessary if the maximum power supplied
to the board never exceeds 100 W, even in worst-case fault);
used inside an enclosure provided with the symbol IEC 60417-5041 (element 1a according to clause 9.5.2 of the IEC 62368-1) on the external part;
used inside an enclosure compliant with all applicable IEC 62368-1 requirements
used along with CPU Heatspreader/heatsinks designed according to the thermal characteristics indicated in the par. 2.2 and to the mechanical characteristics
indicated in par. 2.4. The board in its enclosure must be evaluated for temperature and airflow considerations.
installed in a way that prevents the access to the board from children
The manufacturer which include a SBC-C31 module in his end-user product shall:
verify the compliance with all applicable clauses of the IEC 62368-1 in its own final operating condition;
check that all connections from or to the board are compliant to ES1 requirements;
provide an instructional safeguard against thermal injuries, according to clause 9.4.2 of the above mentioned standard. This instructional safeguard must be
placed both on end-
The board shall be powered by a Power Supply Unit separately approved and classified ES1/PS2 according to the requirements of IEC EN 62368-1.
SBC-C31
SBC-C31 User Manual - Rev. First Edition: 1.0 - Last Edition: 1.0 - Author: A.R. - Reviewed by D.T. - Copyright © 2021 SECO S.p.A.
9