ICA-8DIO4M1-G20-IO
Product Description
LEDs IO1 – IO8
Status
Off
Yellow lit up
All LEDs flashing red
Yellow unchanged
Red lit up
Red LEDs illuminating in sequence
1. Long off, short on
LEDs M1 – M4
Status
Off
Yellow
Red
Red flashing
Red/yellow flashing
MOT3 & MOT4 flashing red alter-
nately
MOT1 & MOT2 flashing yellow alter-
nately
MOT3 & MOT4 flashing red
Note
The LEDs MOT1, MOT2, and IO1 to IO8 are supplied from IO-Link; the LEDs MOT3 and MOT4
are supplied from PWR.
Note
When all LEDs are in the "off" state, a heartbeat (1.9 s off/0.1 s on) is output via all yellow motor
LEDs to signal the general operational readiness of the module. The heartbeat always begins
with a full "off" phase.
Flashing Pattern for Device Identification
In the field, a device can be identified by a flashing pattern. The flashing pattern is activated via
parameter index (127). All LEDs flash in the following pattern:
0
Figure 2.3
Function
Input/output not active
Input/output active
No communication with IO-Link master
1
State of the input/output
Overload or short circuit of the output or supply
No valid firmware or firmware update active
Function
Motor is not running/output is not active
Motor is running/output active (high)
Overload or short circuit at the output (also during motor
operation)
Motor fault (only during motor operation)
Motor supply fuse faulty (only during motor operation)
Motor controller is running, but no communication with
IO-Link controller
•
•
IO-Link controller is running, no communication with
motor controller
•
•
No valid firmware in the motor controller
Erroneous firmware update
1 s
Flashing pattern for device identification
IO-Link supply not present or firmware update active
PWR supply present
IO-Link supply present
PWR supply not present
T
2 s
11
Need help?
Do you have a question about the ICA-8DIO4M1-G20-IO and is the answer not in the manual?