Pc Voltage Supply X10 - Bosch Rexroth IndraMotion MLC Operating Instructions Manual

Table of Contents

Advertisement

Bosch Rexroth AG
Interfaces
Name at the
Connection type
housing
XETH1, XETH2
Ethernet interfaces
10/100/1000 Base-T
XUSB1 to XUSB6 USB interfaces
Internal connections
USB 3.0 interface
mSATA interface
mPCIe interface
2 slots or 4 slots (see
9.9.1 "Available slots per PC
box type" on page
Connections on the PFC extension cards
XF40/XF41
RT Ethernet interfaces
XF08
Profibus DP interface
XF01/XF02
Sercos III interfaces

9.2 PC voltage supply X10

The 24 V DC voltage supply for the control cabinet PC is connected via the "X10"
connection.
All voltages internally required are generated without any electrical isolation via
a DC/DC converter. The connection is designed as spring terminal, SPC 5/3-
ST-7,62, 3-pin, grid 7.62 mm. Connect cables to it with the conductor cross-
sections listed in
terminal at X10" on page
Fig. 9-1: 24 V DC connection, X10, pin assignment
14/87
chapter
19)
tab. 9-1 "Conductor cross-sections permitted for the spring
15.
3
2
1
IndraControl VPB 40.4
Connection type
Mating connector or cable
(at the device)
(from outside)
RJ45 socket, 8-pin RJ45 plug
(Twisted pair, 8-wire)
USB socket, 4-pin,
USB plug, 4-pin
type A
USB socket, 4-pin,
USB plug, 4-pin
type A
mSATA base
mPCIe base
PCI/PCIe
PCI/PCIe card
RJ45 socket, 8-pin RJ45 plug (twisted pair,
8-wire)
D-Sub socket, 9-pin D-Sub plug, 9-pin
RJ45 socket, 8-pin RJ45 plug (twisted pair,
8-wire)
DOK-MLC***-INDRACTRLV4-IT02-EN-P