Operation and Specifications
If the platform should fail to lower, NEVER climb down the elevating
assembly.
Page 2-6
E
L
MERGENCY
OWERING
W A R N I N G
!
The Emergency Lowering Valve for the
X20N, X20W, and X26N is located at the
rear of the machine, above the charger.
The Emergency Lowering Valve for the
X31N is located at the rear of the
machine, to the left of the charger.
1. Open the Emergency Lowering
Valve by pulling and holding the
knob.
2. To close, release the knob. The
platform will not elevate if the
Emergency Lowering Valve is
open.
!
Figure 2-5: Emergency Lowering Valve Handle
Emergency Lowering Knob
060571-005
2.3 - Operation
Emergency Lowering Knob