Set Bar Code Element Width - Dymo LabelWriter SE300 User Manual

Dymo labelwriter se300: user guide
Table of Contents

Advertisement

GS W
DESCRIPTION
Selects the horizontal size of a bar code element. The "Thin"
parameter represents the thickness of the thin bars (in dots). The
"Thick" parameter represents the thickness of the thick bars (in
dots). Each dot measures .0049 inches in 203 dpi and .0073
inches in 138 dpi.
In Code 3 of 9, Interleaved 2 of 5, and Codabar, the thick bar
width is set according to the "Thick" parameter, however, all
other symbologies ignore the "Thick" parameter. The "Thin"
parameter is used by all symbologies.
EXPRESSION
ASCII
Decimal
Hex
PARAMETERS
Thin = thickness of thin bars
Thick = thickness of thick bars
EXAMPLE
For an example of this command's usage, see Appendix A,
page 91, Example 35.
For an example of this command using the Caret feature see page
100, Example.35.
4-68

Set Bar Code Element Width

GS
W
Thin
29
87
Thin
1D
57
Thin
Thick
Thick
Thick