ADTRAN NetVanta 1560-48-370W Quick Start Manual page 2

48-port managed gbe 370w poe+ switch
Table of Contents

Advertisement

f
WARNING!
This equipment is not suitable for use in locations where children are likely to be present.
Installation Overview
To install the switch, you will need to do the following:
1. Mount the switch
2. Connect AC Power
3. Install SFP+ Modules
Installation Steps
To install the NetVanta 1560-48-370W switch, complete the following steps:
Mount the Switch
The switch can be mounted in a 19-inch rack, or on a desk or shelf.
Mounting in a 19-inch Rack
To mount the switch into a 19-inch rack, complete the following steps.
1. Attach the mounting brackets to both sides of the chassis. Insert the provided screws and tighten them with a screwdriver to secure the brackets.
2. Position the chassis in the stationary equipment rack. Allow 1-inch of clearance between units.
3. Have an assistant hold the unit in position, with the oval holes in the brackets aligned with the mounting holes in the rack posts, as you insert two rack screws
and tighten them with the appropriate screw driver.
2
Figure 3. Attaching Brackets to the Switch
617101568PF2-13A