BTL6-E500-M_ _ _ _-E2/E28-KA_ _/KE_ _/LA_ _
Micropulse Transducer - Rod Style
3
Installation (cont.)
Fig. 3-2: Micropulse Transducer BTL6-E500....E2/E28..., installation
3.1

Installation variants

Be sure that no strong
electrical or magnetic
fields are generated in the
direct vicinity of the transducer.
For horizontal mounting of trans-
ducer with stroke lengths greater
than 500 mm, the pressure tube
should be supported or attached
at its end.
Be sure that no strong electrical or
magnetic fields are generated in
the direct vicinity of the
transducer. ➥ ➥ ➥ ➥ ➥ Fig. 3-3.
3.2

Transducer, Installation

The smallest permissible distance
between magnet ring and rod
mounting surface is shown in
Fig. 3-1.
Essentially the BTL transducer can
be attached in two ways in a
toleranced hole – Ø 48 H8 –,
whereby sealing is accomplished
using the O-ring and support ring
supplied:
The body of the transducer is
fixed in place using 3 M5 threaded
studs at 120° spacing.
Threaded stud M5
Fig. 3-3: Installation: at non-magnetizable material
Fig. 3-4: Installation: at magnetizable material
Threaded stud DIN 914 M5x8
a = non-magnetizable material
b = magnet
B
E2
13 mm
E28 11 mm
a = magnetizable material
b = magnet
c = spacer of non-
magnetizable material