– Conducted interference induced by highfrequency fields EN 6100046 Severity level 3 – Magnetic fields EN 6100048 Severity level 4 More detailed information on the guidelines, approvals, and standards is included in the declaration of conformity. www.balluff.com english...
The warnings used here contain various signal words and system. Flawless function in accordance with the are structured as follows: specifications in the technical data is ensured only when using original BALLUFF accessories. Use of any other components will void the warranty. SIGNAL WORD Hazard type and source Opening the transducer or nonapproved use are not...
The magnet defines the position to be measured on the waveguide. An internally generated INIT pulse interacts with the magnetic field of the magnet to generate a torsional wave in the waveguide which propagates at ultrasonic speed. www.balluff.com english...
BTL6-A/C/E/G500-M _ _ _ _ -PF-S115 Micropulse Transducer in a Flat Profile Housing Installation and connection Installing the transducer Captive magnets The following must be observed when installing the NOTICE! magnet: – Avoid lateral forces. Improper installation – Connect the magnet to the machine member with a Improper installation can compromise the function of the joint rod (see Accessories on page 18).
Plug with Fig. 4-3: Dimensions and distances with BTL5-P-3800-2 magnet Fig. 4-7: Dimensions and distances with BTL5-P-4500-1 electromagnet (24 V/100 mA) The measuring range is offset by 4 mm towards the transducer plug (see Figure 4-7). Fig. 4-4: Dimensions and distances with BTL5-P-5500-2 magnet www.balluff.com english...
BTL6-A/C/E/G500-M _ _ _ _ -PF-S115 Micropulse Transducer in a Flat Profile Housing Installation and connection (continued) Electrical connection BKS-S115-... -A500 -G500 -C500 -E500 BKS-S116-... Yellow Not used Gray 0 V Pink Not used Fig. 4-8: Pin assignment of S115 connector (view of connector La (programming input) pins of transducer) Green...
Operating notes – Check the function of the transducer and all associated components on a regular basis. – Take the position measuring system out of operation whenever there is a malfunction. – Secure the system against unauthorized use. www.balluff.com english...
Any desired position of the magnet can be used as the corresponds to activation (high active). null or end point. However, the null and end points may The Balluff BTL7-A-CB02-S115 adjusting box can be used not be reversed. for this (see Accessories on page 19).
Reading new null point ► Move magnet to the new end position. ► Read new end point by activating the programming inputs. ⇒ The current null point remains the same. Before After New end point Fig. 6-3: Reading new end point www.balluff.com english...
BTL6-A/C/E/G500-M _ _ _ _ -PF-S115 Micropulse Transducer in a Flat Profile Housing Teach-in NOTICE! Interference in function LED display Displayed values (example) Teach-in while the system is running may result in malfunctions. ► Stop the system before performing teach-in. At 0…10 V At 4…20 mA Initial situation:...
3. Abort inverting Inverting can be aborted without any changes being saved after the Activate inverting step. ► Briefly activate simultaneously (< 1 s). < 1 s ⇒ Current position value is displayed. LED legend: LED green LED flashing green LED red www.balluff.com english...
BTL6-A/C/E/G500-M _ _ _ _ -PF-S115 Micropulse Transducer in a Flat Profile Housing Resetting all values (reset) NOTICE! Interference in function Resetting the values while the system is running may result in malfunctions. ► Stop the system before performing the reset. The reset function can be used to restore all the settings to the factory settings.
: Use in enclosed spaces and up to a height of 2000 m above sea IEC 60529 level. (when attached) Individual specifications as per Balluff factory standard, resonances excluded : The transducer must be externally connected via a limited- energy circuit as defined in UL 61010-1, a low-power source as defined in UL 60950-1, or a class 2 power supply as defined in UL 1310 or UL 1585.
Page 18
BTL6-A/C/E/G500-M _ _ _ _ -PF-S115 Micropulse Transducer in a Flat Profile Housing Accessories 11.1 Captive magnets 11.3 Floating magnets BTL5-F-2814-1S BTL5-P-3800-2 Ø 4.2 M5x10 Fig. 11-1: Installation dimensions of BTL5-F-2814-1S magnet Fig. 11-4: Installation dimensions of BTL5-P-3800-2 magnet Weight: Approx. 28 g Weight: Approx.
Page 19
Fig. 11-11: Connector type BKS-S116-PU-_ _, outlet switched on and off electrically (actuation with a PLC signal). 11.5 Adjusting box BTL7-A-CB02-S115 Scope of delivery: – Adjusting box – 2 adapter cables, each approx. 0.3 m – Condensed guide www.balluff.com english...
Page 20
BTL6-A/C/E/G500-M _ _ _ _ -PF-S115 Micropulse Transducer in a Flat Profile Housing Type code breakdown BTL6 - A 5 00 - M0500 - PF - S115 Micropulse transducer Interface: A = Analog interface, voltage output 0…10 V G = Analog interface, voltage output −10…10 V C = Analog interface, current output 0.1…20 mA E = Analog interface, current output 4…20 mA Supply voltage:...
Page 21
0.19685039 0.23622047 152.4 0.27559055 177.8 0.31496063 203.2 0.35433071 228.6 0.393700787 Tab. 13-1: Conversion table mm to inches Tab. 13-2: Conversion table inches to mm 13.2 Part label Ordering code Type Serial number Null mark Fig. 13-1: BTL6 part label www.balluff.com english...
Page 22
US Service Center CN Service Center Germany Germany China Balluff GmbH Balluff GmbH Balluff Inc. Balluff (Shanghai) trading Co., ltd. Schurwaldstrasse 9 Schurwaldstrasse 9 8125 Holton Drive Room 1006, Pujian Rd. 145. 73765 Neuhausen a.d.F. 73765 Neuhausen a.d.F. Florence, KY 41042 Shanghai, 200127, P.R.