Balluff BTL5-P User Manual

Balluff BTL5-P User Manual

Micropulse linear transducer digital output / profile housing
Hide thumbs Also See for BTL5-P:

Advertisement

Technical Description / User's Guide
Sensors Worldwide
BTL5-P/I/K/L/M_-M/U_ _ _ _-P-S 32/KA_ _
Micropulse Linear Transducer
Digital Output / Profile Housing

Advertisement

Table of Contents
loading

Summary of Contents for Balluff BTL5-P

  • Page 1 Technical Description / User’s Guide Sensors Worldwide BTL5-P/I/K/L/M_-M/U_ _ _ _-P-S 32/KA_ _ Micropulse Linear Transducer Digital Output / Profile Housing ™...
  • Page 3 Rugged, 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Rod Style Compact Rod Style Balluff - Linear Transducer Generation 5 Output Type Explosion-proof Compact, Rod Style bolt-in Differential start/stop with tri-state Differential stop - leading edge active...
  • Page 4: Table Of Contents

    BTL5-P/I/K/L/M_-M/U_ _ _ _-P-S32/KA_ _ Micropulse Linear Transducer Digital Output / Profile Housing Contents 1 Safety Advisory Safety Advisory ....2 Read this manual before installing and operating the Micropulse Proper application ....2 Transducer. Qualified personnel .... 2 Use and inspection .... 2 Proper application Scope ........
  • Page 5: Function And Characteristics

    BTL5-P/I/K/L/M_-M/U_ _ _ _-P-S32/KA_ _ Micropulse Linear Transducer Digital Output / Profile Housing 2 Function and Characteristics 2.1 Characteristics Available stroke length Micropulse transducers feature: The torsional wave arriving at the and magnets end of the waveguide is absorbed —...
  • Page 6: Floating Magnets

    Installation (cont.) Nominal stroke Mounting brackets with isolation bushings and M5 x 22 cylinder head screws, DIN 912, max. tightening torque 2 Fig. 3-1: Dimensional drawing (BTL5...P-S 32 transducer with floating magnet BTL5-P-3800-2) max. permissible tightening torque 2 Nm Ø 4.2 Fig.
  • Page 7: Captive Magnets

    BTL5-P/I/K/L/M_-M/U_ _ _ _-P-S32/KA_ _ Micropulse Linear Transducer Digital Output / Profile Housing Installation (cont.) Black, Nominal stroke round marking Mounting brackets with isolation bushings and M5 x 22 cylinder head screws, DIN 912, max. tightening torque 2 Nm Fig. 3-5: Dimensional drawing (BTL5...P-KA transducer with captive magnet BTL5-F-2814-1S) Black, round Ball joint "B"...
  • Page 8: Wiring

    BTL5-P/I/K/L/M_-M/U_ _ _ _-P-S32/KA_ _ Micropulse Linear Transducer Digital Output / Profile Housing 4 Wiring Digital, RS485 differential Digital, Single-ended 24 V (P, M, I, K, L, R) 24 V (N) Interrogate + Input Interrogate + Input Interrogate - Input...
  • Page 9: Startup

    BTL5-P/I/K/L/M_-M/U_ _ _ _-P-S32/KA_ _ Micropulse Linear Transducer Digital Output / Profile Housing Wiring (cont.) INIT START/STOP INIT START/STOP +24 V Fig. 4-3: BTL5-P1...KA_ _ with processor controller, wiring example Startup 5.3 Check output values 5.1 Check connections Fault conditions...
  • Page 10: Technical Data

    The following are typical values at DC 24 V and 25 °C. Fully operational after power-up, with full accuracy after warm-up. Values are with BTL5-P-3800-2, BTL5-P-4500-1 or BTL5-P-5500-2 magnet held at a constant offset from the transducer or with captive magnet BTL5-F/M/N-2814-1S (see magnet section for exceptions): Control arm (optional) 7.3 Control signals...
  • Page 11 BTL5-P/I/K/L/M_-M/U_ _ _ _-P-S32/KA_ _ Micropulse Linear Transducer Digital Output / Profile Housing Magnet and Control Arm Diagram Refernces Nominal stroke Fig. 3-1: Dimensional drawing (BTL5...P-S 32 transducer with floating magnet BTL5-P-3800-2) Mounting brackets with isolation bushings and M5 x 22 cylinder head screws, DIN 912, max.
  • Page 12 Phone: (905) 816-1494 Toll-free: 1-800-927-9654 Fax: (905) 816-1411 Web: www.balluff.ca E-mail: balluff.canada@balluff.ca Mexico Balluff de Mexico S.A. de C.V Prol. Av. Luis M. Vega #109 Col. Ampliacion Cimatario Queretaro, QRO 76030 Phone: (++52 442) 212-4882, 224-3583, 224-3171 Fax: (++52 442) 214-0536...

This manual is also suitable for:

Btl5-iBtl5-kBtl5-u-p-s 32Btl5-lBtl5-m-mBtl5-ka

Table of Contents