BTL5-H1_ _-M_ _ _ _-HC/WC-S94
Micropulse Linear Transducer - Rod Style
3

Installation

Mounting
surface
Ø 5 for Hookspanner Ø 65,
tightening torque max. 100 Nm
Fig. 3-1: Transducer BTL5-...HC/WC..., Dimensions
Important Installation Notes:
The contact surface of the trans-
ducer must be completely con-
tacted by the mounting surface.
The O-ring supplied must make a
perfect pressure seal, i.e. the
bevel for the O-ring must be con-
figured exactly as shown in
➥ ➥ ➥ ➥ ➥ Fig. 3-3.
4
english
HC: 40 -1 mm
WC: 2" - 0.04"
Nominal length =
Measuring range
Magnet
Thread size:
HC: M18×1.5
WC: 3/4"-16UNF
To achieve secure mounting, use the
proper nut for the mounting thread.
When tightening the nut, do not
exceed a tightening torque of
100 Nm.
For horizontal mounting of trans-
ducer with stroke lengths greater
than 500 mm, the pressure tube
should be supported or attached at
its end.
Damping zone
not included
unusable area
When installing in a hydraulic cylin-
der, do not allow the magnet ring to
rub against the pressure tube. The
bore diameter in the piston and
cylinder rod should be at least
13 mm.