UENR0612
(Table 115, contd)
Troubleshooting Test Steps
4. Electrical Power Supply to the Diagnostic Connector
A. Use a multimeter to check that battery voltage is present be-
tween terminals A and B of the diagnostic connector.
Note: If the communication adapter is not receiving power, the
LED display on the communication adapter will be off.
5. Electronic Service Tool and Related Hardware
A. Connect the electronic service tool to a different engine.
Note: This process eliminates the electronic service tool and
the related hardware as the fault.
6. Electrical Power Supply to the Electronic Control Mod-
ule (ECM)
A. Check the power supply to the ECM. Refer to Troubleshoot-
ing, "Electrical Power Supply - Test".
Note: If the ECM is not receiving battery voltage, the ECM will
not communicate.

ECM Software - Install

Flash Programming – A method of loading a flash
file into the Electronic Control Module (ECM)
The electronic service tool is utilized to flash program
a flash file into the ECM. The flash programming
transfers the flash file from the PC to the ECM.
Use this process to program the engine flash file to
the existing engine ECM. If the ECM is being
replaced, refer to Troubleshooting, "ECM - Replace"
to flash program a blank ECM.
Flash Programming a Flash File
1. Connect the electronic service tool to the
diagnostic connector.
2. From the menu bar go to the following menu
options:
• Service
• Copy Configuration
• ECM Replacement
This document has been printed from SPI2. NOT FOR RESALE
Values
Results
Electrical power
Result: Battery voltage is not present between terminals A
and B of the diagnostic connector.
Investigate the cause and repair, as necessary.
Result: Battery voltage is present between terminals A
and B of the diagnostic connector.
Proceed to Test Step 5.
Hardware
Result: The same fault occurs on a different engine.
Check the electronic service tool and the related hardware
for faults.
Result: The fault does not occur on a different engine.
Proceed to Test Step 6.
Power to ECM
Result: The power supply to the ECM is incorrect.
Investigate the cause and repair, as necessary.
Result: The power supply to the ECM is OK.
Contact the Dealer Solution Network (DSN).
i06043620
3. Click on "Load From File" at the bottom of the
screen.
4. Once the ECM data has been loaded, click on
"Save to File" at the bottom of the screen. Select a
folder location and click on "Save" .
5. Obtain the part number for the new flash file.
Note: If you do not have the part number for the flash
file, use "PTMI" on the Perkins secured website.
Note: You must have the engine serial number in
order to search for the part number of the flash file.
6. Connect the electronic service tool to the
diagnostic connector.
7. Turn the keyswitch to the ON position. Do not start
the engine.
8. Select "WinFlash" from the "Utilities" menu on
the electronic service tool.
Note: If "WinFlash" will not communicate with the
ECM, refer to Troubleshooting, "Electronic Service
Tool Does Not Communicate".
9. Flash program the flash file into the ECM.