Name
Color
P1-P4
Orange
Green
Off
FX
Orange
Alarm
Red
Off
Module
Green
Off
Adjustable pull up/down resistor for RS-422/485 (150
KΩ or 1 KΩ)

Hardware Installation Procedure

STEP 1: Connect the 12-48 VDC power adapter to the NPort 6450 and
then plug the power adapter into a DC outlet.
STEP 2: For first-time configuration, use a cross-over Ethernet cable to
connect the NPort 6450 directly to your computer's Ethernet cable. For
connecting to a network, use a standard straight-through Ethernet cable
to connect to a hub or switch.
STEP 3: Connect the NPort 6450's serial port(s) to serial device(s).
NOTE The operating temperature of the power adapter in the box is 0 to
40˚C. If your application is out of this range, please use a power
adapter supplied by UL Listed External Power Supply (The power
output meets SELV and LPS and rated 12 - 48 VDC, minimum
0.73A). Moxa has power adapters with wide temperature range
(-40 to 75˚C, -40 to 167˚F), the PWR-12150-(plug type)-SA-T
series, for your reference.
Function
Serial port is receiving data.
Serial port is transmitting data.
Serial port is idle.
Steady on: Ethernet port is idle.
Blinking:
Fiber port is transmitting or receiving
data.
The relay output (DOUT) is open (exception).
The relay output (DOUT) is shorted (normal
condition).
A network module has been detected.
No network module is present.
- 4 -
Dip switch Pin 1 and Pin 2 are
used to set the pull up/down
resistors. The default is 150
KΩ. Turn on dip switch Pin 1
and Pin 2 to set this value to 1
KΩ. Do not use the KΩ setting
with RS-232 mode, since
doing so will degrade the
RS-232 signals and shorten
the communication distance.
Dip switch Pin 3 is used to set
the terminator. Turn on dip
switch Pin 3 to set this value to
120 ohm.