Moxa Technologies NPORT 6600 series Quick Installation Manual
Moxa Technologies NPORT 6600 series Quick Installation Manual

Moxa Technologies NPORT 6600 series Quick Installation Manual

Advertisement

Quick Links

Quick Installation Guide

Moxa Americas:
Toll-free: 1-888-669-2872
Tel:
1-714-528-6777
Fax:
1-714-528-6778
Moxa Europe:
Tel:
+49-89-3 70 03 99-0
Fax:
+49-89-3 70 03 99-99
Moxa India:
Tel:
+91-80-4172-9088
Fax:
+91-80-4132-1045
NPort 6600 Series
Edition 8.0, August 2016
Technical Support Contact Information
www.moxa.com/support
 2016 Moxa Inc. All rights reserved.
Moxa China (Shanghai office):
Toll-free: 800-820-5036
Tel:
+86-21-5258-9955
Fax:
+86-21-5258-5505
Moxa Asia-Pacific:
Tel:
+886-2-8919-1230
Fax:
+886-2-8919-1231
P/N: 1802066500016
*1802066500016*

Advertisement

Table of Contents
loading

Summary of Contents for Moxa Technologies NPORT 6600 series

  • Page 1: Quick Installation Guide

    NPort 6600 Series Quick Installation Guide Edition 8.0, August 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Moxa China (Shanghai office): Toll-free: 1-888-669-2872 Toll-free: 800-820-5036 Tel: 1-714-528-6777 Tel: +86-21-5258-9955 Fax: 1-714-528-6778 Fax: +86-21-5258-5505 Moxa Europe: Moxa Asia-Pacific: Tel: +49-89-3 70 03 99-0...
  • Page 2: Package Checklist

    Overview The NPort 6600 series of serial device servers includes 8-port, 16-port, and 32-port models for connecting larger numbers of serial devices to Ethernet. Some applications now also require better security when transmitting data through a network. The NPort 6600 series of device servers use DES, 3DES, and AES data encryption to provide secure network communication.
  • Page 3: Hardware Introduction

    Hardware Introduction Demonstrated 8 port model to be an example. Reset Button Press the Reset button continuously for 5 second to load factory defaults: Use a pointed object to press the reset button. Release the button after the Ready LED stops blinking. RS-485 adjustable pull high/low resistor (150/1 KΩ) The NPort 6650 has 3 DIP Switches associated with each serial port for configuring the pull high/low resistors for RS-485 applications.
  • Page 4: Rack Mounting

    Function Power is being supplied to the power input. Ready Steady Power is on and the NPort 6600 series is booting up. Blinking: IP conflict, DHCP or BOOTP server not responding, or relay output. Check relay output first. If still blinking, then...
  • Page 5: Hardware Installation Procedure

    Installation CD window opens, click on the Installation button, and then follow the instructions on the screen. To view detailed information about the NPort Search Utility, refer to the pdf version of the “NPort 6600 Series User’s Manual,” which is located in the document directory of the CD.
  • Page 6: Pin Assignments And Cable Wiring

    Pin Assignments and Cable Wiring Pin Assignments (NPort 6610/6650) RS-422, RS-232 2-wire RS-485 4-wire RS -485 – – TxD+ – TxD- – RxD+ Data+ RxD- Data- – – – – Pin Mapping for RS-232 Cables (NPort 6610/6650) NPort6610/6650 Serial Device RJ45 DB9(M) DB9(F) DB25(M) DB25(F) Pin Mapping for RS-422/4W-RS-485 Cables (NPort 6650)
  • Page 7: Power Requirements

    Signals RS-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND RS-422: Tx+, Tx-, Rx+, Rx-, GND RS-485(2W): Data+, Data-, GND RS-485(4W): Tx+, Tx-, Rx+, Rx-, GND RS-485 Data ADDC™ (Automatic Data Direction Control) Direction Serial Communication Parameters Parity None, Even, Odd, Space, Mark Data bits 5, 6, 7, 8 Stop bit(s)