Overview The NPort 6150/6250 Series secure serial device servers provide reliable serial-to-Ethernet connectivity for a wide range of serial devices. The NPort 6150/6250 support TCP Server, TCP Client, UDP, and Pair-Connection operation modes to ensure the compatibility of network software. In addition, the NPort 6150/6250 also support Secure TCP Server, Secure TCP Client, Secure Pair-Connection, and Secure Real COM modes for security critical applications such as banking, telecom, access control, and remote site management.
NPort 6250 Reset Button—Press the Reset Button continuously for 5 sec to load factory defaults. Use a pointed object, such as a straightened paper clip or toothpick, to press the reset button. This will cause the Ready LED to blink on and off. The factory defaults will be loaded once the Ready LED stops blinking (after about 5 seconds).
Serial port was opened by server side Green software. P1, P2 in- use LED Serial port has not been opened by server side software. Adjustable pull high/low resistor for RS-422/485 (150 KΩ or 1 KΩ) Open the back door with a NPort 6150 screwdriver and use the DIP switch to set the pull high/low...
The NPort 6150/6250 can be placed flat on a desktop or other horizontal surface. In addition, you may use the DIN-rail or wall--mount options, as illustrated below. Wall-mount DIN-rail Software Installation Information For the NPort’s configuration, the default IP address of the NPort is 192.168.127.254.
Page 6
Two serial cables for connecting the NPort 6150 to a serial device can be purchased separately. The wiring diagrams for the two cables are shown below. WARNING The use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.