Moxa Technologies NPort 6450 Series Quick Installation Manual

Moxa Technologies NPort 6450 Series Quick Installation Manual

Hide thumbs Also See for NPort 6450 Series:

Advertisement

Quick Links

Quick Installation Guide

Moxa Americas:
Toll-free: 1-888-669-2872
Tel:
1-714-528-6777
Fax:
1-714-528-6778
Moxa Europe:
Tel:
+49-89-3 70 03 99-0
Fax:
+49-89-3 70 03 99-99
Moxa India:
Tel:
+91-80-4172-9088
Fax:
+91-80-4132-1045
NPort 6450 Series
Edition 8.0, August 2016
Technical Support Contact Information
www.moxa.com/support
 2016 Moxa Inc. All rights reserved.
Moxa China (Shanghai office):
Toll-free: 800-820-5036
Tel:
+86-21-5258-9955
Fax:
+86-21-5258-5505
Moxa Asia-Pacific:
Tel:
+886-2-8919-1230
Fax:
+886-2-8919-1231
P/N: 1802064500015
*1802064500015*

Advertisement

loading

Summary of Contents for Moxa Technologies NPort 6450 Series

  • Page 1: Quick Installation Guide

    NPort 6450 Series Quick Installation Guide Edition 8.0, August 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Moxa China (Shanghai office): Toll-free: 1-888-669-2872 Toll-free: 800-820-5036 Tel: 1-714-528-6777 Tel: +86-21-5258-9955 Fax: 1-714-528-6778 Fax: +86-21-5258-5505 Moxa Europe: Moxa Asia-Pacific: Tel: +49-89-3 70 03 99-0...
  • Page 2: Package Checklist

    Overview The NPort 6450 secure serial device servers provide reliable serial-to-Ethernet connectivity for a wide range of serial devices. The NPort 6450 supports TCP Server, TCP Client, UDP, and Pair-Connection operation modes to ensure the compatibility of network software. In addition, the NPort 6450 also supports Secure TCP Server, Secure TCP Client, Secure Pair-Connection, and Secure Real COM modes for security critical applications such as banking, telecom, access control, and remote...
  • Page 3: Hardware Introduction

    Hardware Introduction NOTE The LCD panel is only available with standard temperature models. Reset Button—Press the Reset button continuously for 5 sec to load factory defaults. Use a pointed object, such as a straightened paper clip or toothpick, to press the reset button. This will cause the Ready LED to blink on and off.
  • Page 4: Hardware Installation Procedure

    Name Color Function Orange Steady on: Ethernet port is idle. Blinking: Fiber port is transmitting or receiving data. Alarm The relay output (DOUT) is open (exception). The relay output (DOUT) is shorted (normal condition). Module Green A network module has been detected. No network module is present.
  • Page 5: Software Installation Information

    Software Installation Information The Document & Software CD contains the User’s Manual, NPort Search Utility, and the PComm Lite Suite. Insert the CD and follow the on-screen instructions. Please refer to the User’s Manual for additional details on using the NPort Search Utility and PComm Lite. Pin Assignments and Cable Wiring RS-232/422/485 Pin Assignments (male DB9) RS-422/...
  • Page 6: Environmental Limits

    OS Driver Windows Real COM Drivers: Windows Support 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/8.1/10 (x86/x64), Windows 2008 R2/2012/2012 R2 (x64), Windows Embedded CE 5.0/6.0, Windows XP Embedded Real TTY drivers: Linux 2.4, 2.6, and 3.x Fixed TTY drivers: SCO Unix, SCO OpenServer 5, OpenServer 6, UnixWare 7, UnixWare 2.1, SVR4.2, QNX 4.25, QNX 6, Solaris 10, FreeBSD 5, FreeBSD 6 Configuration...