Step 5
Reconnect the power and communication cable, power-on CBMS to self-check, check whether
the system has returned to normal after replacement
Noted: Check whether all the states of the new module are restored to normal,
including battery cell voltage, temperature, and communication status, which can
be viewed through LCD or monitoring software
14.2.2 Fan replacement
The battery module is cooled by air, and the cooling fan is located behind the module, which is
easy to disassemble and maintain.
Step 1
Remove the fixing plate screws of the fan module
Figure 14.4 remove FAN fixing plate screws
73