collect in the exhaust venting system. The exhaust venting
system should be inspected at least once every year or ton of
pellets burned to determine if cleaning is necessary.
c.
Inspection and Removal – The chimney connector and chimney
should be inspected annually or per ton to determine if a
creosote or fly ash build-up has occurred. If creosote has
accumulated, it should be removed to reduce the risk of a
chimney fire. Inspect the system at the stove connection and
at the chimney top. Cooler surfaces tend to build creosote
deposits quicker, so it is important to check the chimney from
the top as well as from the bottom.
The creosote should be removed with a brush specifically designed
for the type of chimney in use. A qualified chimney sweep can
perform this service. It is also recommended that before each
heating season the entire system be professionally inspected,
cleaned and, if necessary, repaired. To clean the chimney, detach
the vent at the combustion blower transition where it is attached to
the blower.
RECOMMENDED MAINTENANCE SCHEDULE
Burn Pot
Glass
Combustion Chamber
Ashes
Interior Chambers
Heat Exchange Tubes
Combustion Blower Blades
Convection Blower Impeller
Vent System
Gaskets
Hopper (end of season)
Annually or
Daily
Weekly
per Ton
Stirred
Emptied
Wiped
Cleaned
Brushed
Emptied
Vacuumed
2 Passes
Vacuumed/
Brushed
Vacuumed/
Brushed
Cleaned
Inspected
Emptied and
vacuumed
Use this as a guide under average-use conditions. Gasket around
door and door glass should be inspected and repaired or replaced
when necessary. (See "REPLACEMENT PARTS")
REMOVAL AND REPLACEMENT OF BROKEN DOOR GLASS
While wearing leather gloves (or any other gloves suitable for
handling broken glass), carefully remove any loose pieces of glass
from the doorframe. Dispose of all broken glass properly. Return
the damaged door to your dealer for repair or replacement. This
unit's door uses a 5/8" diameter rope gasket. Neither the appliance
owner nor any other unauthorized person(s) should replace the
door glass. An authorized dealer must perform all repairs involving
door glass.