Download Print this page

Breckwell SP4000 Manual page 10

Advertisement

Cleaning heat exchanger tubes – see instructions in
"CLEANING".
Scrape ashes from burnpot.
SHUTDOWN PROCEDURE
Turning your stove off is a matter of pressing the "Power" control
panel switch. The red light will go out. The blowers will continue to
operate until internal firebox temperatures have fallen to a preset
level.
SAFETY FEATURES
a.
Your stove is equipped with a high temperature thermodisc.
This safety switch has two functions.
1.
To recognize an overheat situation in the stove and shut down the
fuel feed or auger system.
2.
In case of a malfunctioning convection blower, the high-
temperature thermodisc will automatically shut down the auger,
preventing the stove from overheating.
NOTE: The thermodisc will reset itself once the stove has cooled.
The manufacturer recommends that you call your dealer if this
occurs as this may indicate a more serious problem. A service call
may be required.
b.
If the combustion blower fails, an air pressure switch will
automatically shut down the auger.
NOTE: Opening the stove door for more than 30 seconds during
operation will cause enough pressure change to activate the air
switch, shutting the fuel feed off. Close the door and press "On/Off"
button to continue operation of your stove.
OPTIONAL THERMOSTAT
A thermostat may help you maintain a constant house temperature
automatically. A millivolt thermostat is required. The control panel
can be set up two ways to operate your stove in thermostat mode.
THERMOSTAT INSTALLATION
A MILLIVOLT THERMOSTAT IS REQUIRED.
Unplug stove from power outlet.
10
FIGURE 24
Remove control board from stove.
The two thermostat wires connect to the terminal block on the
lower left side of the back of the control board.
Insert the wires in the terminal side and tighten the two screws.
MODES
TO SWITCH BETWEEN ANY OF THE THREE MODES THE STOVE
MUST BE SHUT OFF, THE NEW MODE SELECTED, AND THE STOVE
RESTARTED.
MANUAL MODE
USE THIS MODE EXCLUSIVELY IF YOU DO NOT CONNECT AN
OPTIONAL THERMOSTAT
In this mode the stove will operate only from the control panel
as detailed in the "OPERATION" section of this owner's manual.
HIGH/LOW THERMOSTAT MODE
USE THIS MODE ONLY IF YOU CONNECT A THERMOSTAT
When engaged in this mode the stove will automatically switch
between two settings. When warm enough, it will switch to
the #1 or low setting. The room air blower will also slow to its
lowest speed.
The Heat Level Advance setting on the bar graph will stay where
it was initially set. When the house cools below the thermostat
setting, the stove will switch to the feed rate of the heat level
advance setting.
ON/OFF THERMOSTAT MODE
USE THIS MODE ONLY IF YOU CONNECT A THERMOSTAT
In this mode when the home is warm enough the stove will shut
off. The fans will continue to run until the stove cools.
When the home cools below the thermostat setting, the stove
will automatically restart and run at the last feed rate setting.
NOTE: When in "high/low" or "on/off" thermostat mode –
Do not operate the stove higher than the #3 setting.
Set damper control rod approximately 1/4" to 1/2" out. This will
vary depending on elevation and weather conditions. Observe
stoves operation and adjust damper as necessary.
OPERATING SAFETY PRECAUTIONS
PLEASE READ THIS!
Hot while in operation. Keep children, clothing, and furniture
away. Contact may cause skin burns.
If you notice a smoldering fire (burnpot full but no visible flame)
AND a heavy smoke buildup in firebox, im mediately TURN
OFF the stove, but DO NOT unplug it. Do not open the door,
change the damper setting or tamper with any controls on
the stove. Wait until firebox clears, and blowers shut down, do
as instructed in "PRE-START-UP CHECK" and "BUILDING A
FIRE", then attempt to restart the fire. If the problem persists
contact your dealer.
WARNING: DO NOT ADD PELLETS TO THE BURNPOT BY HAND
AT ANY TIME, A DANGEROUS CONDITION COULD RESULT.
WARNING: DURING THE START UP CYCLE; 1) DO NOT OPEN
THE VIEWING DOOR; 2) DO NOT OPEN THE DAMPER MORE
THAN 1/4"; 3) DO NOT USE THE FUEL FEED BUTTON (UNLESS
PRIMING THE AUGER AFTER RUNNING OUT OF PELLETS). A
DANGEROUS CONDITION COULD RESULT.
Pellets should be stored in a dry place. The pellets should not

Advertisement