Final Tests; Maintenance - GiBiDi SL 820 Instructions For Installation Manual

Electromechanical gearmotors
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 18
22
UK
MANUAL UNLOCKING OPERATION [19]
If the gate needs to be operated manually, insert the triangular key provided in the dedicated seat on the gearmotor
[19] and turn it anticlockwise. Manually open or close the gate. To relock the gearmotor, fully turn the triangular key
clockwise. Manually and carefully move the gate until it locks.
Should you wish to replace the unlocking device provided on the gearmotor with an unlocking device with
personalised key, proceed as follows:
1- remove the triangular unlocking key (if inserted);
2- with a star-tip screwdriver undo the screw inside the triangular key unlocking device [20];
3- remove the unlocking device [21- 22];
4- take the unlocking device with personalised key and fit the two springs in their housings (make sure that the
key is in horizontal position [23]);
5- Fit the new device in its seat, then press and turn the key 90° anticlockwise [24]. Secure the device with the
dedicated pins in the two side holes, exercising slight pressure for better coupling [25].

FINAL TESTS

Close the gearmotor casing. Power the system and run a complete opening and closing cycle checking that:
Ÿ the gate moves smoothly;
Ÿ the safety devices function properly;
Ÿ the foundation plate is firmly in place;
Ÿ the gate assembly is in compliance with the current EN 12453 EN 12445 standards;
For further details and information on the reference standards, visit our site: www.gibidi.com

MAINTENANCE

Periodically check the gate structure, in particular:
Ÿcheck perfect functioning of the rails;
Ÿcheck that the rack has not lowered with the weight of the gate, since it would weigh down on the gearmotor. Should
this be the case, raise the rack and retighten the screws lower down in the slot, or lower the gearmotor using the
adjusting screws [8];
Ÿevery 6 months check good functioning of the safety devices;
Ÿunlock the operator and check that there are no points of friction along the entire travel of the gate;
Ÿcheck proper functioning of the unlocking device (see the relative paragraph);
Ÿcheck that there is no dirt or fragments on the pinion.
Gi.Bi.Di. S.r.l. reserves the right to change the technical data without prior notice in relation to product development.
SL

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl 830Sl 840