The manual unlocking device is situated on the support bracket of the gate and allows unlocking the gate both from
the inside and the outside of the property.
To manually open the gate, operate as follows:
• Uncover the lock sliding off the protective cap as shown in 22 .
• Insert the unlocking key in the lock 22 and turn it.
• Pull the lever towards you and manually move the leaf.
• Turn the key for an additional 180° and remove it from the lock.
WARNING: it is essential that the key is turned for at least 180° during the manual operation.

RESTORING NORMAL OPERATION

To restore normal operation, act as follows
• Strip the lock sliding the protection as in 22 .
• Insert the unlocking key in the lock 22 and turn it for 180°.
• Manually move the leaf until the lock couples on the locking bracket.
• Take the key back to its original position and remove it.
• Close the protective lock sliding cap.
FITTING THE ELECTRIC LOCK 24 - 25
It is recommended to use an electric lock for leaves larger than 2.5 m and in any case for blind or flush panel doors
À
ELECTRIC LOCK
Á
ELECTRIC LOCK FASTENING PLATE
Â
LATCH COUPLING
Ã
ND-STOP FOR LATCH COUPLING
Ä
LATCH
Å
THROUGH CYLINDER (ON REQUEST)
Æ
GATE

FINAL TESTING

Power the system and run a complete opening and closing cycle checking that
• The safety devices function properly;
• The gate moves smoothly;
• The solidity of the foundation plate;
• The gate assembly conforms to EN 12453 and EN 12445.
• For further details and information on the reference standards, visit our website:
www.gibidi.com
[
[
]
:
[
]
[
]
[
] [
]
]
: