Plumbing

The Miele Waterproof system

As long as your dishwasher has been
installed correctly, the Miele waterproof
anti-leak system will protect you from
water damage throughout its lifetime.

Water intake

Water in the dishwasher must
not be used as drinking water.
- The dishwasher must be connected
to the water supply in strict
accordance with current local and
national water authority regulations.
- The water used must at least comply
with national regulations for drinking
water quality.
If the water supply has a high iron
content, there is a danger of
corrosion occurring on items being
cleaned in the dishwasher, as well as
the machine itself.
If the chloride content of the water
exceeds 100 mg/l, the risk of
corrosion to items being cleaned in
the dishwasher will be further
increased.
- In certain regions (e.g. mountainous
regions), the water composition may
cause precipitates to form, requiring
the use of softened water for the
dishwasher.
- A device for preventing the return
flow of water is not necessary, as this
commercial dishwasher conforms to
the applicable standards for the
protection of drinking water.
However, if the vessel is moored and
connected to a dock supply, then it is
the responsibility of the dock to
ensure the water supply is
adequately protected.
- The water pressure (flow pressure at
the take-off point) must be between
30 and 1000 kPa (0.3 and 10 bar).
If the water pressure is lower than
this, the fault message
will appear in the display (see
"Problem solving guide").
If the water pressure is too high, a
pressure reducer valve must be fitted.
- A stopcock valve with a
thread must be provided on site. It
should be easily accessible so that
the water supply can be turned off
when the dishwasher is not in use.
- The DN 10 inlet hose is approx. 1.5 m
long terminating in a
thread. A 1.5 m long flexible metal
extension hose tested to 140 bar
(14,000 kPa) is available as an
optional accessory if required. On no
account may the inlet filter be
removed.
Installation
Water intake
3
/
inch male
4
3
/
 inch female
4