Oneida Air Systems Supercell XSK000035 Owner's Manual

Oneida Air Systems Supercell XSK000035 Owner's Manual

High-pressure, 35/55 gallon

Advertisement

OWNER'S MANUAL
Supercell
®
High-Pressure
Dust Collector
35/55 Gallon
# XSK000035
# XSK000055
Appearance may vary slightly
Rev: 07/20/2020
Doc. #ZBM000038

Advertisement

Table of Contents
loading

Summary of Contents for Oneida Air Systems Supercell XSK000035

  • Page 1 OWNER’S MANUAL Supercell ® High-Pressure Dust Collector 35/55 Gallon # XSK000035 # XSK000055 Appearance may vary slightly Rev: 07/20/2020 Doc. #ZBM000038...
  • Page 3: Table Of Contents

    Table of Contents System Start-Up Information System Speci cations Wall Bracket Dimensions System Dimensions with 35 Gallon Drum System Dimensions with 55 Gallon Drum System Contents 35/55 Gallon Drum Maintenance Troubleshooting F.A.Q. Recommended Accessories Warranty Information Notes oneida-air.com...
  • Page 4: System Start-Up Information

    1,500 cfm (cubic feet per minute). is exempts some small operators from the NFPA code 664, but other codes may apply in your jurisdiction. Consult your local Fire Marshal for help. Additional information can be found in NFPA Code Book 664. Oneida Air Systems...
  • Page 5 System Start-Up Information (Continued) e customer assumes the responsibility for contacting their insurance underwriter regarding speci c application requirements of explosion venting or if additional re protection and safety equipment may be required. 5. DO NOT use this product to collect ammable dust or ammable vapors! - Fire or explosion may occur! 6.
  • Page 6: System Speci Cations

    35 Gallon: 72-7/8"; 2,108 mm without Universal Drum Dolly 55 Gallon: 84-1/4"; 2,140 mm without Universal Drum Dolly Overall Weight 35 Gallon: 95 lbs 55 Gallon: 102 lbs e Supercell requires a 20 Amp outlet receptacle to be installed by a licensed electrician. Oneida Air Systems...
  • Page 7: Wall Bracket Dimensions

    Wall Bracket Dimensions Nominal dimensions shown. Dimensions subject to slight variations in manufacturing. 1/2" 13 mm 15-1/4" 388 mm 2" 51 mm 4" 6" 102 mm 152 mm 8" 203 mm 16" 406 mm 20" 508 mm Floor Dimensions from oor to top of the wall bracket 35 Gallon: 38-1/2"...
  • Page 8: System Dimensions With 35 Gallon Drum

    If you purchased the Universal Drum Dolly, add an additional 4" to the height of the unit. 20" Top View 508mm 23-3/4" 508mm 23-1/2" 508mm 21-9/16" 548 mm 24-1/4" 616 mm 71-7/8" 1,826 mm 47-5/8" 1210 mm 22-1/4" 565 mm Oneida Air Systems...
  • Page 9: System Dimensions With 55 Gallon Drum

    System Dimensions with 55 Gallon Drum Nominal dimensions shown. Dimensions subject to slight variations in manufacturing. Allow for an additional 24" of clearance above the Motor Assembly to allow for its removal during lter replacement and other maintenance. If you purchased the Universal Drum Dolly, add an additional 4" to the height of the unit. Top View 20"...
  • Page 10: System Contents 35/55 Gallon Drum

    55 Gallon Drum w/ Clamp SMS040000 Rear Support Brace Please unpack the parts carefully and con rm you have received each item listed here. *Some components are pre-installed at the factory and are listed here for your convenience. Oneida Air Systems...
  • Page 11 FINISH: NAME: 14Ga Galv THE INFORMATION CONTAINED IN THIS FPX040001 - Filter Hold Down 14ga rev 3 DRAWING IS THE SOLE PROPERTY OF Oneida Air Systems Inc. AND SHALL SIZE TOL: PART NO. FPX040001 NOT BE USED OR DISCLOSED TO...
  • Page 12 49-7/8" 978 mm 1267 mm the Universal Drum Dolly, add an additional 4". Note: If you wish to mount your system higher than the recommend height, you will need additional 5" dia. ex hose. FIG. 2 10 Oneida Air Systems...
  • Page 13 Assembly Instructions (Continued) Place a mark through the Template's (G1) Mark Mark Here Here paper at each indicated crosshair (four keyway holes and one center hole), then remove the Template (G1) from the wall [FIG. 3a]. Measure 15-1/4" up from the center hole and mark a straight level line to help with the install of the Rear Support Brace (G13) [FIG.
  • Page 14 [FIG 6]. FIG. 6 Slide the Wall Bracket (F) down so that the fastener is snugly inside the smaller section of each keyhole [FIG 7]. FIG. 7 Oneida Air Systems, Inc.
  • Page 15 Assembly Instructions (Continued) Tighten these four fasteners to secure the Wall Bracket (F) to the wall [FIG. 8]. Note: If installing over drywall, avoid overtightening as it may damage the wall. FIG. 8 Fasten the Rear Support Brace (G13) to the wall using your own suitable hardware [FIG.
  • Page 16 Rubber Washer (G9), and Whiz-Lock Nut (G11) as shown in [FIG 12]. Note: Ensure that the Whiz-Lock Nuts are torqued down so that the rubber washers are rmly compressed - this will prevent air leaks. FIG. 12 Oneida Air Systems, Inc.
  • Page 17 Assembly Instructions (Continued) Install the three remaining Hex Head Bolts (G7), Flat Washers (G8), Rubber Washers (G9), and Whiz-Lock Nuts (G11) to the three remaining holes in the Cyclone’s (E) upper ange [FIG 13]. Note: Ensure that the Whiz-Lock Nuts are torqued down so that the rubber washers are rmly compressed - this will prevent air leaks.
  • Page 18 (by roughly 50%). FIG. 16 Open and slide the Ring Clamp (D) over the assembly so that it rests outside the upper ange of the Cyclone (E) [FIG. 17]. FIG. 17 Oneida Air Systems, Inc.
  • Page 19 Assembly Instructions (Continued) Install the Barrel Gasket (G2) onto the rounded, bottom edge of the Motor Assembly (A). e Barrel Gasket (G2) should be oriented so that the "ribbed" side is facing downwards [FIG. 18]. FIG. 18 Attach one end of the Vinyl Tubing (G16) onto the barbed tting located underneath the Motor Assembly's (A) plastic cowl.
  • Page 20 Clamp's cotter pin [FIG. 22]. FIG. 22 Take the Vinyl Tubing (G16) and route it through the closest retaining hole located in the back corner of the Wall Bracket (F) [FIG. 23]. Either Hole FIG. 23 Oneida Air Systems, Inc.
  • Page 21 Assembly Instructions (Continued) Connect the Dust Sentry (J) to the smaller power cord on the Motor Assembly's (A) magnetic starter. e Dust Sentry (J) should be mounted in a highly visible area using adhesive strips or the Sentry's two mounting holes [FIG.
  • Page 22 (sold separately). Not all ultrasonic Dust Sentry models contain an additional hole. FIG. 27 Seal the Drum (L) closed using the provided clamp [FIG. 28]. Collar for Flex Hose Clamp FIG. 28 Oneida Air Systems, Inc.
  • Page 23 Assembly Instructions (Continued) Attach the other end of the Vinyl Tubing (G16) onto the Nylon Elbow (G17A) installed on the lower section of the Drum (L). Push the Vinyl Tubing onto the tting so that all the barbs are covered [FIG. 29]. G17A FIG.
  • Page 24: Maintenance

    3. Unlatch the Ring Clamp (D) at the base of the motor section and allow it to hang freely. Remove the motor section and set aside. 8. Replace the motor section and re-latch the drum clamp around the motor section. Oneida Air Systems, Inc.
  • Page 25 Maintenance (Continued) Emptying the Drum Cleaning out the Cyclone When rst using the dust collector, check the Drum If the drum becomes over lled and the cone is Window (K1) regularly to get an idea of how o en packed with dust: it needs to be emptied.
  • Page 26 4. Remove the plenum plate and set aside (there is no against the bottom of the motor. hardware securing the plenum plate, it is compressed between the cowling and the motors). Oneida Air Systems, Inc.
  • Page 27 Maintenance (Continued) 9. Place motors back on the motor plate. Replace the motor 11. Re-secure the motor hold down plate using the ve 5/16- hold down plate, ensure wires sit above the plate, ensure 18" Nylock Nuts. Note: DO NOT OVERTIGHTEN. Install the provided the tabs on the motors line up with the notches on the hold down plate.
  • Page 28: Troubleshooting

    2. Review the Maintenance section on how to replace the motor. If you continue to experience difficulty with your dust collector, call Oneida Air Systems’ Customer Service Department at 1-866-387-8822 or email support@oneida-air.com. Oneida Air Systems, Inc.
  • Page 29: F.a.q

    What dust can be collected? Oneida Air Systems' dust collectors are designed and tested for wood and wood dust. ey can and have been used e ectively for various other dusts and chips, such as drywall dust, paper dust, agricultural dust, metal chips and other forms of debris.
  • Page 30: Recommended Accessories

    • Turn your dust collector into vacuum system with this complete hose accessory kit. • Crush-resistant hose features smooth inner wall for minimal air resistance. • Includes common vacuum head accessories including crevice tool, oor tool, and more! 28 Oneida Air Systems...
  • Page 31 Recommended Accessories (Continued) 5" Hose Quick Connect Adapter Kit #DQK050000 • Simplify 5" ex-hose connections to your tools and dust collection systems/ductwork. • Made from heavy-gauge, galvanized steel. • Includes both the male (crimped) and female (non-crimped) Hose Quick Connect ttings. 4"...
  • Page 32: Warranty Information

    Oneida Air Systems makes every e ort to accurately represent our products and prices, however Oneida Air Systems reserves the right to make changes to products and prices at any time. As a manufacturer, Oneida Air Systems reserves the right to change product speci cations at any time in an e ort to achieve better quality products.
  • Page 33: Notes

    Notes oneida-air.com...
  • Page 34 Regardless of where you purchased your system, if you have any questions or issues with missing / damaged parts, please call Oneida Air Systems rst to let us help resolve your problem. We fully stand behind the quality of our product and place the utmost value on our customer’s satisfaction.

This manual is also suitable for:

Supercell xsk000055

Table of Contents