Oneida Air Systems Dust Gorilla Pro Smart Boost XGK030105H-S35VP Owner's Manual

Oneida Air Systems Dust Gorilla Pro Smart Boost XGK030105H-S35VP Owner's Manual

Advertisement

Owner's Manual / Mode d'emploi
Oneida Air Systems, Inc. was founded in 1993 to bring cost effective, state-of-the-art dust collection systems
and material handling ductwork to woodworking shops. OAS designs and manufactures industrial grade dust
collection systems that create a practical, safe and healthy work place environment.
Oneida Air Systems, Inc. a été fondée en 1993 pour mettre le coût, les systèmes état -of-the-art de dépoussiérage et de
manutention conduits efficace pour les ateliers de menuiserie. OAS conçoit et fabrique des systèmes de classe industri-
elle de la poussière de collecte qui créent un environnement pratique, sûr et sain lieu de travail.
Smart Technology
U.S. Pat. # -
8,491,685
Filter Flame-Guard ™
Arrestor - U.S. Pat. #
8,496,719
ZBM000104
3 / 5hp
3hp -
XGK030105H-S35VP
XGK030105
5hp-
XGK050105H-S35VP
XGK050105H-SH-S
with
Appearance may vary slightly /
L'apparence peut varier légèrement

Advertisement

Table of Contents
loading

Summary of Contents for Oneida Air Systems Dust Gorilla Pro Smart Boost XGK030105H-S35VP

  • Page 1 Oneida Air Systems, Inc. a été fondée en 1993 pour mettre le coût, les systèmes état -of-the-art de dépoussiérage et de manutention conduits efficace pour les ateliers de menuiserie. OAS conçoit et fabrique des systèmes de classe industri-...
  • Page 2: System Start-Up Information

    System Start-Up Information Read the installation and maintenance instructions as well as the recommended safety practices in this manual. / Lisez les instructions d’installation et d’entretien ainsi que les pratiques de sécurité recommandées dans ce manuel. WARNING / AVERTISSEMENT Do not operate Fan / Blower unless Fan Housing is attached DANGER to Cyclone body and Dust Drum is in place.
  • Page 3 System Contents / le contenu du système FPZ000018 BHX020005B SXI002108 BXI030118C / BXI050118C FCS183600HF SCX002109 Optional 35 & 55 Gal. Drum Kits - OEK550901 / OEK350901 STX002100 SEX550900 ACB120000 DHF090000 FPX000001 SES350000 SES550000 Optional Stand - STZ212300 Optional Wall Optional Leg Bracket - Extention Kit - FPX010018...
  • Page 4 System Contents / le contenu du système Suggested Tools: 9/16” Wrench Filter 9/16” Socket Wrench Grounding Wire 1/2” Wrench 1/2” Socket Wrench Motor Tape Ruler Cowling 8ft. Ladder Scissors On / Off Box AFB155175 - (7) Hook AFW180000 - (7) &...
  • Page 5: Specifications

    Specifications System 1625 Max. CFM Performance Height w/ 35 Gallon Drum: 94” System Footprint w/ Ext. Cartridge: 36” x 48” Inlet Diameter: Welded 7” w/ Neutral Vane Dimensions Powder Coated Paint Finish Over Heavy Gauge Steel Seam-Welded Cyclone 35 Gal. - 94” U.S.
  • Page 6 Dimensions For Minimum Mounting Heights w/ 36” Filter & 35 / 55 Gal. Drums *Dimensions subject to slight variation in manufacturing. Attention: All metal ductwork should go inside of the inlet. All flexible hose ductwork should go on the outside of the inlet. Shown with optional stand.
  • Page 7 Fan Housing Assembly Instructions / Assemblée Instructions Instructions for Attaching Motor Plate to Fan Housing / Make sure that the fan housing is oriented Instructions pour Fixation de la plaque du moteur au like this diagram before you attach clips logement Fan.
  • Page 8 Assembly Instructions Do NOT use hook on motor to lift unit. With all assemblies, make sure rectangular air outlet is oriented on Fan/Blower housing as you are looking down as in Pg. 6 This is very important. / Avec toutes les assemblées, assurez-vous que la sortie d’air rectangulaire est orien- tée sur le logement Fan / ventilateur que vous êtes à...
  • Page 9 Put gasket material around top rim of barrel, outside of the bolt holes, again making sure that there is no gap where the ends meet. Make sure that the housing’s outlet is oriented in the direction that fits your shop layout and the pre-installed nuts are on the underside of the top. Attach Fan Blower Housing (BHX020005B) to barrel (SXI002108) on floor.
  • Page 10 Stand Assembly / Tenez Assemblée 35 Gal. Stand - STZ212300 Stand Kit Contents / Tenez-Contenu du kit 21” 21” 30” 30” Optional Stand Leg Extension for use with 55 Gal. Drum or Universal Drum Dolly STX212304 - 21-23 Inch Leg Extension 1.
  • Page 11 Wall Bracket Assembly / Ensemble de console murale Optional 1. The collector will seem quieter if the outlet is aimed away from the area people tend to work. Slots in the brack- ets are .406” x 1.00”. Note: Bolts included to mount bracket to collector. Hardware NOT included to mount to wall. / Le collecteur sera sembler plus si la sortie vise loin de la zone gens ont tendance à...
  • Page 12 Filter Assembly / filtrer Assemblée Make sure your filter is in the proper position for your ductwork set up. See filter positions pg.18 for further External 39” Filter Assembly information. *Silencer Included / Silencieux Inclus Outlet - Fig. 1 1. Attach gasket (RGZ000000) to housing outlet, making sure there is no gap where ends meet.
  • Page 13 3. Attach Plenum to outlet using the included (7) 3/8 x 1” bolts with 2 wash- Filter Plate - Fig. 2 ers and a whiz nut, making sure the support hanger on the Plenum is at the 4 hole side is near dust bottom.
  • Page 14: Starter Assembly

    Flex Hose Connection Cone to Drum / Tuyau Flex connexion Cone Drum If you are having trouble getting your drum Drum Grounding Wire out to empty it, you can cut down the flex / Tambour Fil de terre hose to give yourself more room. Just make sure that the drum lid tightly seals to the drum To attach the Drum and that there are no leaks in the flex hose...
  • Page 15 Directions for Cleaning External Filter / Itinéraire pour nettoyage filtre externe All steps should be done with a dust mask and eye protection. Proper filter cleaning should not be neglected. A dirty filter can affect dust collector operation and filter life./ Toutes les étapes doivent être faites avec un masque anti-poussière et des lunettes de protection.
  • Page 16: Electrical Wiring

    Filter Grounding Wire Figure 1 Attach the ring terminal on the braided ground wire from the motor to a bolt on the filter plate, under the nut. Then attach the alligator clip to the filter cage as shown in Fig. 1. If you need to extend the wire, you can use any 16 ga. copper stranded wire.
  • Page 17 Fan Motor Maintenance / Moteur de ventilateur Entretien Per Baldor specifications, their 2 pole motors (3,600 rpm) are to be relubricated every 5,500 hours. / Par spécifica- tions Baldor, leurs deux moteurs de pôles (3600 rpm) doivent être graissés toutes les 5500 heures. Table 1 - Service Conditions / Conditions de service Ambient Temperature Type of Bearing / Type...
  • Page 18: Replacement Filter

    Accessories Stand Leg Extension Part # Description Bolt Together Stand STZ212301 Leg Extension Kit STZ212300 - 35 Gal. Stand Adjustable extensions allow use of 55 gal. drum and Universal Drum Dolly on 35 and 55 gal. dust drums. Dust Containers Replacement Filter 55 Gal.
  • Page 19: Troubleshooting

    Possible Filter Positions - Not Possible Filter Positions - Fan housing and cyclone bolt holes are drilled at 45 degree increments. Some orientations are not possible. Please check your design. Filter hits inlet pipe. Inlet Inlet WALL BRACKET WALL BRACKET WALL BRACKET 2.5 HP SUPER GORILLA 2.5 HP SUPER GORILLA...
  • Page 20 Poor Dust Pick-Up at Woodworking Machines Dust pauvres Pick-Up à Machines à bois Caused By: Causée Par: Une mauvaise rotation du moteur - Exécution arrière Improper motor rotation - Running backwards will réduira aspiration de 30% reduce suction by 30% Vérifiez la longueur des tronçons de conduits et diamètres de Check length of duct runs and duct diameters compared to conduite par rapport à...
  • Page 21 Fire Hazards / Risques D’incendie Read before installing and operating Lire avant d’installer et d’exploitation. Wood shaping and cutting processes generate wood Processus de mise en forme et la coupe de bois génèrent des copeaux de bois , les copeaux et la poussière . Ces matériaux chips, shavings and dust.
  • Page 22 The customer assumes the responsibility for contacting Le client assume la responsabilité de communiquer avec leur their insurance underwriter with regard to specific applica- souscripteur d’assurance à l’égard des exigences spécifiques à tion requirements of explosion venting or if additional fire l’application d’explosion ventilation ou si la protection incendie protection and safety equipment may be required.
  • Page 23 Oneida Air Systems shall be tried in the State of New York, County of Onondaga. / Bons Oneida Air Systems ™ les produits fabriqués par Oneida Air Systems, pour une période de 1 an ou plus selon le produit , à l’acheteur original de la date d’achat , sauf indication contraire .
  • Page 24 Oneida Air Systems se réserve le droit d’apporter des modifications aux produits et les prix à tout moment. En tant que producteur, Oneida Air Systems se réserve le droit de modifier la conception et les spécifications des produits à tout moment.
  • Page 25 Optional Ductwork Infinite Adjustability Made in the USA Adjustable, Fast Installation Now you can make the infinite adjustments to fit any length requirement. The exclusive adjustability of our fittings makes Gorilla Duct™ the clamp- together duct that is infinitely adjustable. All fittings (elbows, branches, reducers...

Table of Contents