Tilted, X and Tilted, Y: When the robotic
lawnmower is standing horizontally the value
should be max ±3. Inclination up and to the left
give negative values.
Normal position: YES indicates that the mower
is standing in a normal position and NO indicates
that the mower is upside down.
The Info - Sensors - Temp display mode shows the
mower's temperature, measured by a temperature
sensor on the main circuit board.
2.1.3 History
The History - Messages - Fault messages display
mode shows the last 50 fault messages that have been
displayed when the mower has stopped.
The By date display mode shows for each message:
Position in the message list, e.g. 1.
Message title
Date and time when the message was set.
The By frequency display mode show for each
message:
Position in the message list. The faults are
sorted according to frequency with the most
frequent at the top.
Message title
The number of times this fault has occurred
since the latest fault message reset.
The History - Messages - Info messages display mode
shows the last 50 messages that the mower has
registered but did not stop for. If the mower solved the
problem itself, the fault is then registered as an info
message, but it is registered as a fault message if the
mower cannot solve the problem and stops as a result.
Info messages can be displayed according to date
or number in line with the fault message section above.
By selecting History - Messages - Reset messages both
fault and info messages are deleted from the history list.
2. SPECIAL MENU FUNCTIONS
Status
Mower:
Temp
22°C
English - 19