Urinal flush plate for Prevista Visign for Style 21
▶
Place the brass nut on the cartridge valve.
INFO!
Check that the sealing element is properly positioned.
▶
Place the cartridge valve on straight and carefully screw in (fine
thread).
Tightening torque: 5 Nm
▶
Screw in the cartridge valve (size 27).
▶
Open the shut-off valve.
▶
Checking for leak tightness.
Handling