7.2.4

Flushing-out of sanitization agent out of water side (e.g. P3 Ansep CIP from Ecolab)

Pressurize the water line to the cooler with CO
valves. This makes it easier to flush out any remaining agent from the system.
Close the gas again and depressurize the unit via the dispense valves.
Install a new water filter cartridge and reconnect the unit via the filter to the mains water line again
(refer to filter manufacturer guidelines in case the filter needs priming prior to use).
In case a hygiene filter is being used on the dispenser, it must be ensured that the new filter
cartridge is inserted prior to flushing the system with water. This ensures that a just sanitized system
is not being contaminated again by using poor quality mains water to flush out any remaining
sanitizing agent. Spray the filter head and the connecting position of the filter cartridge with an
adequate sanitizing spray to avoid any introduction of bacteria again.
Open the mains water supply. Pull the safety relieve valve on the carbonator bowl until only clean
water leaves the valve, to ensure that there are no residues of sanitizing agent left in the head area
of the carbonator bowl.
Open the CO
2
Dispense sufficiently water from the post-mix valves to ensure that no sanitizing agent is left in the
system.
Depending on the unit type (Over counter dispenser / large soda circuit installation with long python
runs, etc.) the amount of water that needs to be dispensed may vary.
Attention! It must be ensured, that no cleaning / sanitizing agent remains in the dispense system
after service (risk of health injuries)! The prove that all agent residues have been removed must
be tested with indicator or test papers (contact agent manufacturer) & must be documented
Dispense from each tap a few beverages to fully put the system back into operation again. The
cleaning / sanitization procedure must be documented accordingly and the documentation must
remain at the cooler (this may vary depending on local regulations).
gas supply to the carbonator and reconnect the carbonator pump to the power supply.
IntelliBlue R134 Kuwait
pressure and dispense all sanitizing agent from the