4 - Installation
4.1 - Counter flange's installation
Fig. 1C
COUNTER FLANGE
COUNTER FLANGE
• Shape the central section of the 4 sides of counter flange Y in order to adjust them to the hull curve (Fig. 1C).
• Lay the properly-cut counter flange and check that the four
sides fit the hull, or adjust them until they do fit in the posi-
tion where the counter flange is meant to be fixed.
WARNING: keep into account the minimum dimen-
sions for the final positioning of the hinge (see fig. 12
to page 32).
Fig. 2
• On the hull, Mark with a felt-tip pen the internal perimeter
of the counter flange (fig. 2).
30
CUT LINE
HULL
CUT LINE
HULL
BTR185 INSTALLATION AND USE MANUAL - REV009A
CUT LINE
Fig. 3
350
280
mm
• Remove the counter flange and mark the cutting area:
350 x 280 mm (13" 25/32 x 11" 1/32) (fig. 3).
BTR185
COUNTER FLANGE
BOW
COUNTER FLANGE
95
mm
mm
EN