Dvi-I Connector; Led Indicators - Advantech ITA-5831 Series User Manual

Fanless embedded industrial computer with 6th gen intel core i processor for railway applications
Hide thumbs Also See for ITA-5831 Series:
Table of Contents

Advertisement

2.3.7

DVI-I Connector

ITA-5831 reserves the main display output as DVI-I as a default. There is the option
to convert this to DVI-D +VGA via a Y-cable.
Table 2.12: DVI-I Connector Pin Definitions
Pin
Signal Name
1
T.M.D.S. data2-
2
T.M.D.S. data2+
3
Ground
4
VGA DCC clock
5
VGA DCC data
6
DDC clock
7
DDC data
8
Analog vertical sync
9
T.M.D.S. data1-
10
T.M.D.S. data1+
11
Ground
12
Ground
13
Ground
14
+5V power
15
Ground
2.3.8

LED Indicators

The ITA-5831 front panel features LEDs that are used to indicate system health and
active status. The LED indicator behaviors are explained in the table below.
Item
LED
1
PWR
2
HDD
3
FAULT_SYS
4
Battery
Pin
16
17
18
19
20
21
22
23
24
C1
C2
C3
C4
C5
Status Color
Description
On
Green
The system is powered on and secure.
Off
On
Yellow
Data is being received/transmitted
Off
Not active
On
Red
System fault alarm
Off
Yellow
Battery still has charge
On
Red
Battery fully discharged
Blinking red Battery low charge alarm
Off
Battery is fully charged
15
Signal Name
Hot plug detect
T.M.D.S. data0-
T.M.D.S. data0+
Ground
Ground
Ground
DVI detect
T.M.D.S. clock+
T.M.D.S. clock-
Analog red
Analog green
Analog blue
Analog horizontal sync
Ground
ITA-5831 User Manual

Advertisement

Table of Contents
loading

Table of Contents